GESTION DE LA CONTAMINATION DANS LES SYSTEMES DE REFROIDISSEMENT POUR LES GENERATEURS SUPRACONDUCTEURS. 3. MESURES DE LA CONCENTRATION EN IMPURETES DANS UN GENERATEUR SUPRACONDUCTEUR HESPER 1.

MANAGEMENT OF CONTAMINATION IN COOLING SYSTEMS FOR SUPERCONDUCTING GENERATORS. 3. IMPURITY CONCENTRATION MEASUREMENTS EVOLVED FROM A SUPERCONDUCTING GENERATOR-HESPER 1.

Auteurs : NITTA T.

Type d'article : Article

Résumé

AVANT D'ENTREPRENDRE LE REFROIDISSEMENT JUSQU'A 4,2 K, IL EST IMPORTANT DE PROCEDER A UNE OPERATION DE PURIFICATION EN FAISANT CIRCULER UN GAZ D'HELIUM A TRAVERS UN PURIFICATEUR COMPRENANT UN ADSORBEUR CRYOGENIQUE. POUR LA CONCEPTION DE CET ADSORBEUR CRYOGENIQUE, IL EST NECESSAIRE DE CONNAITRE LES QUANTITES DE GAZ ET DE COMPOSANTS PROVENANT DES GENERATEURS SUPRACONDUCTEURS. ON PRESENTE UNE NOUVELLE METHODE D'ANALYSE DES TRACES D'IMPURETES, AINSI QUE LES RESULTATS DESESSAIS SUR LES TAUX DE DEGAGEMENT DE GAZ EN FONCTION DU TEMPS, EN UTILISANT LE GENERATEUR SUPRACONDUCTEUR HESPER 1.

Détails

  • Titre original : MANAGEMENT OF CONTAMINATION IN COOLING SYSTEMS FOR SUPERCONDUCTING GENERATORS. 3. IMPURITY CONCENTRATION MEASUREMENTS EVOLVED FROM A SUPERCONDUCTING GENERATOR-HESPER 1.
  • Identifiant de la fiche : 1992-0072
  • Langues : Anglais
  • Source : Cryogenics - vol. 30
  • Date d'édition : 09/1990

Liens


Voir d'autres articles du même numéro (81)