Document IIF
Impact de l'encrassage sur la performance du filtre : essais sur plusieurs types d'évaporateurs.
The impact of fouling on the performance of filter: evaporator combinations.
Auteurs : YANG L., BRAUN J. E., GROLL E. A.
Type d'article : Article, Article de la RIF
Résumé
This paper presents results of experiments performed on different combinations of five types of filters of varying efficiencies (MERV4, 6, 8, 11, and 14) and four types of evaporator coils with depths and fin geometries under clean and fouled conditions. The fouled conditions were obtained after injection of 600 g (1612 g/m2 of coil face area) of dust upstream of the filter-coil combination, which was meant to simulate a year of operation in the field. The air-side pressure drops of the coils and filters and air-side effective heat transfer coefficients of the coils were determined from the measurements under the clean and fouled conditions. Depending upon the filter and coil, the coil pressure drops increased in the range of 6-30% for an air velocity of 2.54 m/s. The impact was significantly greater for tests performed without an upstream filter (the coil pressure drops increased from 43 to 200%). The largest relative effect of fouling on pressure drop occurs for coils with fewer rows, primarily due to higher fin densities. The impact of fouling on air-side effective heat transfer coefficients was found to be relatively small, which ranged from -14 to 4%. In some cases, heat transfer was actually enhanced due to additional turbulence caused by the presence of dust. However, with large dust deposits, heat transfer is degraded because the dust also acts as insulation and creates an uneven air velocity.
Documents disponibles
Format PDF
Pages : 489-498
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : The impact of fouling on the performance of filter: evaporator combinations.
- Identifiant de la fiche : 2007-0640
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 3
- Date d'édition : 05/2007
Liens
Voir d'autres articles du même numéro (16)
Voir la source
-
The impact of evaporator fouling and filtration...
- Auteurs : YANG L., BRAUN J. E., GROLL E. A.
- Date : 05/2007
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 3
- Formats : PDF
Voir la fiche
-
Accelerating-particle-deposition method for qui...
- Auteurs : ZHUANG D., DING G., YANG Y., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
An experimental study of the air-side particula...
- Auteurs : AHN Y. C., CHEONG S. I., JUNG Y. M., et al.
- Date : 17/07/2006
- Langues : Anglais
- Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
A literature review on air side heat exchanger ...
- Auteurs : SARFRAZ O., BACH C. K.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental comparison of the impact of air-si...
- Auteurs : BELL I., GROLL E. A.
- Date : 12/07/2010
- Langues : Anglais
- Formats : PDF
Voir la fiche