IIR document
The impact of fouling on the performance of filter: evaporator combinations.
Author(s) : YANG L., BRAUN J. E., GROLL E. A.
Type of article: Article, IJR article
Summary
This paper presents results of experiments performed on different combinations of five types of filters of varying efficiencies (MERV4, 6, 8, 11, and 14) and four types of evaporator coils with depths and fin geometries under clean and fouled conditions. The fouled conditions were obtained after injection of 600 g (1612 g/m2 of coil face area) of dust upstream of the filter-coil combination, which was meant to simulate a year of operation in the field. The air-side pressure drops of the coils and filters and air-side effective heat transfer coefficients of the coils were determined from the measurements under the clean and fouled conditions. Depending upon the filter and coil, the coil pressure drops increased in the range of 6-30% for an air velocity of 2.54 m/s. The impact was significantly greater for tests performed without an upstream filter (the coil pressure drops increased from 43 to 200%). The largest relative effect of fouling on pressure drop occurs for coils with fewer rows, primarily due to higher fin densities. The impact of fouling on air-side effective heat transfer coefficients was found to be relatively small, which ranged from -14 to 4%. In some cases, heat transfer was actually enhanced due to additional turbulence caused by the presence of dust. However, with large dust deposits, heat transfer is degraded because the dust also acts as insulation and creates an uneven air velocity.
Available documents
Format PDF
Pages: 489-498
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: The impact of fouling on the performance of filter: evaporator combinations.
- Record ID : 2007-0640
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 3
- Publication date: 2007/05
Links
See other articles in this issue (16)
See the source
Indexing
-
The impact of evaporator fouling and filtration...
- Author(s) : YANG L., BRAUN J. E., GROLL E. A.
- Date : 2007/05
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 3
- Formats : PDF
View record
-
Accelerating-particle-deposition method for qui...
- Author(s) : ZHUANG D., DING G., YANG Y., et al.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
An experimental study of the air-side particula...
- Author(s) : AHN Y. C., CHEONG S. I., JUNG Y. M., et al.
- Date : 2006/07/17
- Languages : English
- Source: 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
View record
-
A literature review on air side heat exchanger ...
- Author(s) : SARFRAZ O., BACH C. K.
- Date : 2016/07/11
- Languages : English
- Source: 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Experimental comparison of the impact of air-si...
- Author(s) : BELL I., GROLL E. A.
- Date : 2010/07/12
- Languages : English
- Formats : PDF
View record