Impact énergétique de la surchauffe associée à un compresseur semi-hermétique dans un système frigorifique transcritique au CO2.
Energy impact of the superheat associated to a semihermetic compressor in a transcritical CO2 refrigeration plant.
Auteurs : LLOPIS R., SÁNCHEZ E., CABELLO R., et al.
Résumé
This work presents the evaluation, from an energy point of view, of the effects of the superheat associated with the cooling of the electrical motor of semihermetic compressors in carbon dioxide refrigeration plants. The analysis is based on 84 experimental tests, which cover a wide range of operating conditions of an experimental test facility (evaporating temperature from -17.0 to 0.0ºC, compressor speed from 1150 to 1600 rpm, and discharge pressures from 74.2 to 104.9 bar.) In the paper, a parametric model of the compressor and its validation are presented. The model is used to estimate the energy impact of the superheat associated to the electrical motor cooling by comparing the actual performance of the plant with the simulated behaviour without considering that superheat. Results show a maximum reduction in cooling capacity of 20% and in efficiency of 23%.
Documents disponibles
Format PDF
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy impact of the superheat associated to a semihermetic compressor in a transcritical CO2 refrigeration plant.
- Identifiant de la fiche : 2011-0038
- Langues : Anglais
- Source : IIR/Eurotherm sustainable refrigeration and heat pump technology conference. Proceedings of the Eurotherm Seminar No. 88, Stockholm, Sweden, June 13-16, 2010.
- Date d'édition : 13/06/2010
Liens
Voir d'autres communications du même compte rendu (49)
Voir le compte rendu de la conférence
Indexation
-
Influence of the superheat associated to a semi...
- Auteurs : SÁNCHEZ D., TORRELLA E., CABELLO R., et al.
- Date : 04/2010
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 30 - n. 4
Voir la fiche
-
Numerical analysis and experimental validation ...
- Auteurs : RIGOLA J., RAUSH G., PÉREZ-SEGARRA C. D., et al.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche
-
Measurements on a two-stage CO2-compressor.
- Auteurs : REKSTAD H., NEKSÅ P., PISANO G.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche
-
Experimental investigation of the dynamics of a...
- Auteurs : MA Y., GAN Y., PENG X., et al.
- Date : 14/07/2008
- Langues : Anglais
- Source : 2008 Purdue Conferences. 19th International Compressor Engineering Conference at Purdue & 12th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
Numerical analysis of CO2 transcritical cycles ...
- Auteurs : RIGOLA J., ABLANQUE N., PÉREZ-SEGARRA C. D., et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche