INFLUENCE D'UN ECRAN CONTRE L'INFILTRATION D'AIR EXTERIEUR SUR LA CONDENSATION ET L'ACCUMULATION D'EAU DANS LES CAVITES DE PAROIS A CHARPENTE ISOLEE.

EFFECT OF AN EXTERIOR AIR-INFILTRATION BARRIER ON MOISTURE CONDENSATION AND ACCUMULATION WITHIN INSULATED FRAME WALL CAVITIES.

Résumé

UNE SERIE D'ESSAIS DE LABORATOIRE A ETE EFFECTUEE DANS DES ENDROITS OU DE L'AIR INTERIEUR CHAUD ET HUMIDE CIRCULE A TRAVERS DES CAVITES DES PAROIS. 3 SEGMENTS DE MUR ONT ETE MONTES DANS UNE CHAMBRE CLIMATIQUE. LES ESSAIS ONT D'ABORD ETE EFFECTUES SUR LES SEGMENTS DE MUR SANS ECRAN CONTRE L'INFILTRATION D'AIR ET ONT ETE REPETES APRES INSTALLATION D'UN ECRAN. LES RESULTATS INDIQUENT QUE L'ECRAN CONTRE L'INFILTRATION D'AIR INSTALLE ENTRE LEREVETEMENT EXTERIEUR ET LE REVETEMENT INTERIEUR PROVOQUAIT UNE REPARTITION DE L'EAU PLUS REGULIERE PAR REDUCTION DE L'ACCUMULATION DE LA CONDENSATION DANS LES MATERIAUX DE CONSTRUCTION ET QUE LA TENEUR EN EAU LA PLUS ELEVEE DU REVETEMENT EXTERIEUR APPARAISSAIT AVEC UN FROID MODERE, TANDIS QUE LA PLUS FORTE ACCUMULATION D'EAU DANS LA FIBRE DE VERRE APPARAISSAIT LORS DE FROID PLUS INTENSE.

Détails

  • Titre original : EFFECT OF AN EXTERIOR AIR-INFILTRATION BARRIER ON MOISTURE CONDENSATION AND ACCUMULATION WITHIN INSULATED FRAME WALL CAVITIES.
  • Identifiant de la fiche : 1986-2441
  • Langues : Anglais
  • Date d'édition : 1985
  • Source : Source : ASHRAE Trans.
    vol. 91; n. 2A; 545-559; 6 fig.; 5 tabl.; 7 ref.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.