SI LE GRADIENT DE PRESSION, PROVENANT DE L'ECOULEMENT DE VAPEUR AU-DESSUS DE LA SURFACE COURBE, EST INCLUS DANS LE BILAN DE QUANTITE DE MOUVEMENT POUR LA PELLICULE DE CONDENSAT, ON MONTRE QU'IL ENTRAINE UN COEFFICIENT DE TRANSFERT DE CHALEUR PLUS ELEVE AU-DESSUS DE LA MOITIE ANTERIEURE DU TUBE. DANS CERTAINES CIRCONSTANCES, LE CALCUL DE L'EPAISSEUR DE LA PELLICULE DE CONDENSAT AUTOUR DU TUBE N'EST PAS POSSIBLE POUR LA PARTIE INFERIEURE OU LA CONTRAINTE DE CISAILLEMENT DE LA SURFACE ET LE GRADIENT DE PRESSION AGISSENT DANS DES SENS OPPOSES. ON A OBTENU DES SOLUTIONS NUMERIQUES POUR DE LARGES DOMAINES DES PARAMETRES SANS DIMENSIONS APPROPRIES ET ON LES A UTILISEES POUR OBTENIR DES EXPRESSIONS PRECISES DU COEFFICIENT DE TRANSFERT DE CHALEUR MOYEN POUR L'ENSEMBLE DU TUBE QUAND LE TERME DE GRADIENT DE PRESSION A PEU D'IMPORTANCE.