Intérêt d’un refroidisseur à absorption d’ammoniac-eau pour améliorer la performance d’une turbine à gaz en circuit fermé durant les périodes de pic de la demande, en comparaison avec un refroidisseur centrifuge.
Interest of ammonia-water absorption chiller to enhance closed cycle gas turbine performance during peak demand comparison with centrifugal chiller.
Numéro : pap. 1214
Auteurs : TAUVERON N., BOUDÉHENN F., POUVREAU J., et al.
Résumé
Communication présentée sous forme de poster lors de la conférence. The study concerns a heat-to-power cycle at a maximal temperature of 515°C generating 300 MWe. The specificity of the work is to consider an alternative cycle to traditional Rankine machine in order to avoid high pressure steam. The selection falls on a high pressure nitrogen turbo-compressor in a recuperated and intercooled Brayton cycle. Within a regulatory framework, the system is required to participate in the primary and secondary frequency settings. This leads of having the capacity to keep a reserve of electrical power to be provided to the grid on demand coming from the electrical network management. A very effective means is to cool the fluid at compressor inlet. Furthermore thermal energy storage tanks are used to charge and discharge thermal energy produced by a chiller. Two technologies of chillers are compared to accomplish cooling: ammonia-water absorption chiller and HFC (HydroFluoroCarbons) centrifugal chiller. Criteria for evaluation are: size, net power production and CAPEX (CAPital EXPenditure).
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Interest of ammonia-water absorption chiller to enhance closed cycle gas turbine performance during peak demand comparison with centrifugal chiller.
- Identifiant de la fiche : 30023759
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Date d'édition : 18/06/2018
- DOI : http://dx.doi.org/10.18462/iir.gl.2018.1214
Liens
Voir d'autres communications du même compte rendu (177)
Voir le compte rendu de la conférence
-
Second law analysis of a novel cycle concept fo...
- Auteurs : SCHWAMBERGER V., JOSHI C., SCHMIDT F. P.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
A hybrid single-stage absorption refrigeration ...
- Auteurs : AYOU D. S., ASFAND F., BRUNO J. C., et al.
- Date : 10/09/2012
- Langues : Anglais
- Source : 4th Jordanian IIR International Conference on Refrigeration and Air Conditioning. Proceedings: Amman, Jordan, September 10-12, 2012.
- Formats : PDF
Voir la fiche
-
Extended operational flexibility of trigenerati...
- Auteurs : HILLIGWEG A.
- Date : 09/05/2013
- Langues : Anglais
- Source : 5th Conference on Ammonia Refrigeration Technology. Proceedings: Ohrid, North Macedonia, May 9-11, 2013.
- Formats : PDF
Voir la fiche
-
THERMAL STORAGE WITH AMMONIA ABSORPTION REFRIGE...
- Auteurs : HOLLDORFF G.
- Date : 23/04/1990
- Langues : Anglais
Voir la fiche
-
Sta se moze ocekivati od apsorpcione rashladne ...
- Auteurs : KOSI F., BURAZER J., MILOVANCEVIC U., et al.
- Date : 09/2011
- Langues : Serbe
- Source : KGH (Klimatizacija Grejanje Hladenje) - vol. 40 - n. 3
Voir la fiche