Document IIF

L'utilisation du refroidissement cryogénique rapide et le noyau ferromagnétique augmentent grandement l'efficacité d'un convertisseur linéaire à induction dynamique.

The use of fast cryogenic cooling and ferromagnetic core greatly increases efficiency of a linear induction-dynamic converter.

Numéro : pap. n. 12

Auteurs : BOLYUKH V. F., OLEKSENKO S. V., KATKOV I. L.

Résumé

The effects of cryogenic cooling of active elements by liquid nitrogen and the use of a ferromagnetic core on the efficiency of the linear induction-dynamic converter are considered. A mathematical model uses a set of coupled electromagnetic, thermal and mechanical equations. The experimental studies has confirmed the basic theoretical concepts and computational data that cryogenic cooling permits to increase the converter efficiency greater than in case of the use a ferromagnetic core alone. However, the high efficiency can be provided by only if cryogenic cooling of the armature is explored.

Documents disponibles

Format PDF

Pages : 8 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : The use of fast cryogenic cooling and ferromagnetic core greatly increases efficiency of a linear induction-dynamic converter.
  • Identifiant de la fiche : 30011229
  • Langues : Anglais
  • Source : Cryogenics 2014. Proceedings of the 13th IIR International Conference: Prague, Czech Republic, April 7-11, 2014.
  • Date d'édition : 07/04/2014

Liens


Voir d'autres communications du même compte rendu (51)
Voir le compte rendu de la conférence