L'utilisation sans risque de l'ammoniac comme frigorigène dans les zones urbaines.
Safe use of ammonia as a refrigerant in urban areas.
Auteurs : HAUKÅS H. T.
Résumé
Non-industrial use of ammonia as a refrigerant has shown an increasing trend during the last 10-15 years, especially in the Nordic countries, along with increasing pressure on the HFCs. Ammonia use in populated areas requires additional safety issues to be addressed. In the paper a strategy for safe use of ammonia is discussed, including methods for minimising ammonia release and methods to minimise the consequences of a release. Provided that realistic release scenarios are analysed and relevant measures taken to minimise identified hazards, it is the author's opinion that ammonia can be safely used for practically any purpose where it is found of interest technically.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Safe use of ammonia as a refrigerant in urban areas.
- Identifiant de la fiche : 30002844
- Langues : Anglais
- Source : 4th Conference on Ammonia Refrigeration Technology. Proceedings: Ohrid, North Macedonia, April 14-16, 2011.
- Date d'édition : 14/04/2011
Liens
- Voir les traductions : Uso seguro del amoniaco como refrigerante en zonas urbanas.
Voir d'autres communications du même compte rendu (30)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Froid industriel, commercial et domestique : généralités;
Systèmes à compression;
Ammoniac - Mots-clés : Sécurité; Ammoniac; Synthèse; Fuite; Frigorigène
-
Uso seguro del amoniaco como refrigerante en zo...
- Auteurs : HAUKÅS H. T.
- Date : 02/2012
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 40 - n. 444
- Formats : PDF
Voir la fiche
-
Jednosterpena ili dostepena kompresija.
- Auteurs : JEKEL T. B., REINDL D. T.
- Date : 09/2010
- Langues : Serbe
- Source : KGH (Klimatizacija Grejanje Hladenje) - vol. 39 - n. 3
Voir la fiche
-
Ammonia as a replacement for medium sized modul...
- Auteurs : PEARSON A.
- Date : 12/07/2010
- Langues : Anglais
- Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Commercial refrigeration systems with CO2 as re...
- Auteurs : JAVERSCHEK O.
- Date : 07/09/2008
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
Voir la fiche
-
Commercial refrigeration systems with CO2 as re...
- Auteurs : JAVERSCHEK O.
- Date : 02/2009
- Langues : Anglais
- Source : IIF, Note Inf./IIR, Inf. Note/Bull. IIF-IIR/www.iifiir.org - vol. 89 - n. 2009-1
- Formats : PDF
Voir la fiche