Document IIF

Le problème de l'élaboration d'une équation d'état pour le HFE-347mcc, un frigorigène de la nouvelle génération.

A challenge to develop an equation of state for a new generation refrigerant, HFE-347mcc.

Résumé

Experimental studies of the thermodynamic properties of heptafluoropropyl methyl ether (HFE-347mcc), which is expected to replace R11, are summarized in the forms of vapour-pressure, saturated and compressed liquid density correlations and a virial equation of state for vapour phase. Enthalpy calculation for the present refrigerant based on the developed models is performed, which enables the cycle performance evaluation with HFE-347mcc for a heat pumping system.

Documents disponibles

Format PDF

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : A challenge to develop an equation of state for a new generation refrigerant, HFE-347mcc.
  • Identifiant de la fiche : 2000-1203
  • Langues : Anglais
  • Source : 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
  • Date d'édition : 19/09/1999

Liens


Voir d'autres communications du même compte rendu (447)
Voir le compte rendu de la conférence