Document IIF
Les effets de la géométrie d'un évaporateur à tubes à ailettes sur la performance de pompe à chaleur en conditions de déshumidification.
The effects of fin-and-tube evaporator geometry on heat pump performance under dehumidifying conditions.
Auteurs : ERDEM S.
Type d'article : Article, Article de la RIF
Résumé
A heat pump tumble dryer model was developed to investigate the effects of evaporator geometry on drying time and energy consumption. The model was validated using experimental data available in the literature. The effects of the evaporator's geometrical specifications on heat and mass transfer and pressure drops on both sides of the evaporator were investigated. Then, the energy consumption and drying time of the dryer were determined. The results indicated that the energy consumption is reduced by 12% when the number of rows in the evaporator is increased from 2 to 4. Increasing the number of columns from 2 to 4 could reduce energy consumption by 8%. The energy consumption increases by 18% when the outer diameter of the tube is increased from 6 mm to 10 mm. Increasing the longitudinal tube pitch from 10 mm to 30 mm leads to a 21% increase in energy consumption.
Documents disponibles
Format PDF
Pages : 35-45
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : The effects of fin-and-tube evaporator geometry on heat pump performance under dehumidifying conditions.
- Identifiant de la fiche : 30015205
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 57
- Date d'édition : 09/2015
Liens
Voir d'autres articles du même numéro (25)
Voir la source
Indexation
-
Thèmes :
Evaporateurs, condenseurs et autres échangeurs thermiques;
Pompes à chaleur à usage industriel;
Efficacité energétique, économie d'énergie - Mots-clés : Application domestique; Géometrie; Tube ailette; Consommation d'énergie; Déshumidification; Séchage; Pompe à chaleur; Performance; Évaporateur
-
Energy, exergy, economic, and environmental ana...
- Auteurs : MA X., DU Y., LEI B., WU Y.
- Date : 04/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 160
- Formats : PDF
Voir la fiche
-
Study of using a capillary tube in a heat pump ...
- Auteurs : BENGTSSON P., BERGHEL J.
- Date : 07/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 67
- Formats : PDF
Voir la fiche
-
Experimental study on performance improvement o...
- Auteurs : YANG P., YANG Y., LIU Y.
- Date : 11/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 155
- Formats : PDF
Voir la fiche
-
Effects of applying vapor-liquid adjustment in ...
- Auteurs : CHEN J., WEN X., LI J., CHEN Y., LUO X., LIANG Y., HE J.
- Date : 02/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 158
- Formats : PDF
Voir la fiche
-
A Critical Review on the Use of Shallow Geother...
- Auteurs : AHMED A. A., ASSADI M., KALANTAR A., SLIWA T., SAPIŃSKA-ŚLIWA A.
- Date : 06/2022
- Langues : Anglais
- Source : Energies - vol. 15 - n. 12
- Formats : PDF
Voir la fiche