Document IIF
Les influences des caractéristiques de fonctionnement d'un détendeur électronique (EEV) sur la stabilité opérationnelle d'un système de conditionnement d'air à détente directe contrôlé par un EEV.
The influences of the operating characteristics of an Electronic Expansion Valve (EEV) on the operational stability of an EEV controlled direct expansion air conditioning system.
Résumé
This paper reports on a study on the influences of the operating characteristics of a proportional–integral (PI) controlled Electronic Expansion Valve (EEV) on the operational stability of a direct expansion (DX) air conditioning (A/C) system. Using the classical control theory, EEV's PI settings and time constant of EEV's temperature sensor were analyzed. The theoretical analysis results using the classical control theory were further verified experimentally using an experimental DX A/C system. The study results showed that a larger proportional or integral gain would lead to a high chance for the EEV–evaporator control loop to become unstable, while slowing down the rate of degree of superheat (DS) signal transfer by increasing EEV's time constants may help mitigate system's operational instability. The results confirmed that the operating characteristics of an expansion valve in a refrigeration system could impact its operational stability.
Documents disponibles
Format PDF
Pages : 394-406
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : The influences of the operating characteristics of an Electronic Expansion Valve (EEV) on the operational stability of an EEV controlled direct expansion air conditioning system.
- Identifiant de la fiche : 30018605
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 69
- Date d'édition : 09/2016
Liens
Voir d'autres articles du même numéro (37)
Voir la source
Indexation
-
A modeling study on the operational stability o...
- Auteurs : XIA Y., DENG S.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Effects of electronic expansion valve tube arra...
- Auteurs : ZHOU S., ZHAN F., ZHU T., DING G., LIU H., CHEN W., CHEN H.
- Date : 05/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 161
- Formats : PDF
Voir la fiche
-
A simulation study on the operational stability...
- Auteurs : XIA Y., DING Q., SHU J., et al.
- Date : 07/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 103
- Formats : PDF
Voir la fiche
-
Experimental study on whistling noise behavior ...
- Auteurs : ZHOU S., ZHANG F., DING G., ZHU T., MENG J., WANG Q.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Performance characteristics of a residential ai...
- Auteurs : KIMURA DE CARVALHO B. Y., HRNJAK P.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche