Mauvaise distribution du frigorigène diphasique et optimisation de la conception dans de nouveaux échangeurs de chaleur équipés de tubes à microcanaux laminés alternativement (ALMT) avec collecteurs verticaux.

Two-phase refrigerant maldistribution and optimization design in novel alternatively-laminated-microchannel-tube (ALMT) heat exchangers with vertical headers.

Auteurs : GUO W., ZHAO R., HU K., HUANG D., ZHAO Y.

Type d'article : Article de la RIF

Résumé

The novel alternatively-laminated-microchannel-tube (ALMT) heat exchanger contains two pairs of vertical headers and alternatively laminated microchannel flat tubes, which realizes high-efficient heat transfer between water and refrigerant and shows energy-saving potential in large-scale air conditioners. However, the microchannel flat tubes are upright inserted into vertical headers and are susceptible to refrigeration maldistribution. In this article, two-phase refrigerant maldistribution and optimization design in ALMT heat exchangers with vertical headers are studied experimentally and numerically. Refrigerant maldistribution is experimentally measured and its flow behaviors are explored with CFD simulations. The R410A is used as the working fluid. Results show that more liquid refrigerant is supplied to middle tubes but less to both ends under phase separation and gravity. Therefore, the decentered orifice plate (DOP) and parallel multi-chamber (PMC) are designed to improve refrigerant distribution. Both DOP and PMC promote gas-liquid phase mixing by accelerating refrigerant flow. The DOP creates the nested loop flow and PMC forms separate chambers inside vertical header to distribute refrigerant to each flat tube uniformly. Moreover, the formation conditions for nested loop flow are established. The average standard deviation of refrigerant flow rate reduces from 0.21 to 0.07 with DOP, and to 0.03 with PMC, respectively.

Documents disponibles

Format PDF

Pages : 290-303

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Two-phase refrigerant maldistribution and optimization design in novel alternatively-laminated-microchannel-tube (ALMT) heat exchangers with vertical headers.
  • Identifiant de la fiche : 30031906
  • Langues : Anglais
  • Sujet : Technologie
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 151
  • Date d'édition : 07/2023
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2023.03.001

Liens


Voir d'autres articles du même numéro (33)
Voir la source