Document IIF

Maximisation de l'efficacité des cycles frigorifique à absorption solaire d'ammoniac-eau : Analyse exergétique, impact de la concentration, et optimisation avancée avec l'apprentissage automatique GBRT et l'optimiseur FHO.

Maximizing efficiency in solar ammonia–water absorption refrigeration cycles: Exergy analysis, concentration impact, and advanced optimization with GBRT machine learning and FHO optimizer.

Auteurs : AL-RBAIHAT R., ALAHMER H., AL-MANEA A., ALTORK Y., ALRBAI M., ALAHMER A.

Type d'article : Article de la RIF

Résumé

A detailed analysis of energy and exergy is conducted on a single-effect solar ammonia–water (NH3–H2O) absorption refrigeration cycle (ARC) using TRNSYS and EES software. Considering the physical and chemical exergies, the exergy destruction rate (ĖD) in each component of the system is calculated, highlighting its contribution to the overall ĖD. The study explores the effects of varying refrigerant mass flow rate (ṁᵣ) and ammonia concentration in strong and weak solutions (Xs and Xw) on key performance parameters, including coefficient of performance (COP), exergy efficiency (ĖD), and overall ĖD across a range of generator temperatures (Tg). In this study, a gradient boosting regression tree (GBRT) is employed as a supervised machine-learning technique for classification and regression problems, utilizing boosting to enhance conventional decision tree predictions. The Fire Hawk Optimizer (FHO) approach is also utilized to optimize performance parameters, maximizing COP and while minimizing Tg and ĖD. The GBRT models are developed using available experimental and simulation data, revealing relationships between variables (ṁᵣ, Xs, Xw, and Tg) and outcomes (COP, ĖD, and overall ĖD). The results revealed that the generator exhibits considerable ĖD regardless of operating conditions, underscoring its pivotal role in the ARC. It emerges as the primary ĖD contributor (50 %), followed by the evaporator (17 %) and the absorber (15 %). However, ĖD associated with the recooler, pump, and expansion valves is negligible in comparison. Optimization results reveal that, when minimizing Tg and ĖD, the highest COP and ĖD at Tg of 373.15 K reach 0.8081 and 0.46, respectively.

Documents disponibles

Format PDF

Pages : 31-50

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Maximizing efficiency in solar ammonia–water absorption refrigeration cycles: Exergy analysis, concentration impact, and advanced optimization with GBRT machine learning and FHO optimizer.
  • Identifiant de la fiche : 30032308
  • Langues : Anglais
  • Sujet : Technologie
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 161
  • Date d'édition : 05/2024
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2024.01.028

Liens


Voir d'autres articles du même numéro (20)
Voir la source