Mécanismes pour améliorer la performance du transfert de chaleur grâce à l'enrobage de l'évaporateur à l'aide d'un film d'un conditionneur d'air automobile.

[In Chinese. / En chinois.]

Auteurs : CAO X., ZHANG M., OUYANG Q.

Type d'article : Article

Résumé

The heat transfer process of automobile air-conditioner evaporators without hydrophilic film was analysed. It is suggested that hydrophilic film can affect the heat transfer performance of automobile air-conditioner evaporators from three aspects, i.e., effective heat transfer area, heat transfer coefficient and temperature difference. Effective heat transfer area coefficient was proposed and measured experimentally. A mathematical model was established to simulate the heat transfer processes of both the evaporator plating with hydrophilic film and the one without hydrophilic film, and the model was verified by experiments. The results show that the heat transfer coefficient decreases but effective heat transfer area and temperature difference increase, and thus the total heat transferred increases by 5% for the evaporator plating with hydrophilic film.

Documents disponibles

Format PDF

Pages : 54-57

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : [In Chinese. / En chinois.]
  • Identifiant de la fiche : 2009-0350
  • Langues : Chinois
  • Source : Journal of Refrigeration - vol. 29 - n. 3
  • Date d'édition : 06/2008

Liens


Voir d'autres articles du même numéro (6)
Voir la source