Mesures détaillées des écoulements d'air générés par des diffuseurs circulaires situés au plafond.
Detailed measurements of airflow characteristics of circular ceiling diffusers.
Auteurs : CHUAH Y. K., HU S. C., BARBER J. M.
Résumé
These proceedings in two volumes contain 198 papers presented at this conference, held in Reading, United Kingdom, 9-12 July 2000. The air distribution in occupied spaces is a major issue of public concern. It is widely recognized that the quality of air and the nature of airflow can affect the health of occupants and the energy consumed in buildings and transport vehicles. Chapters are: Volume 1: Keynote papers: provide good air quality for people and improve their productivity; the quality of buildings is equal to the indoor climate quality; optimised indoor air quality and energy saving strategies for quality buildings in Mediterranean climates: compatible objectives with comfort and environment issues? sustainability, energy and cost. indoor environment; predictive methods; air distribution. Volume 2: ventilation strategies; system efficiency; applications.
Détails
- Titre original : Detailed measurements of airflow characteristics of circular ceiling diffusers.
- Identifiant de la fiche : 2002-0342
- Langues : Anglais
- Source : Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
- Date d'édition : 09/07/2000
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (67)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Autres équipements de conditionnement d'air
- Mots-clés : Géometrie; Mesure; Vortex; Diffuseur d'air; Air; Débit; Conditionnement d'air
-
A performance evaluation of the HVAC-based nozz...
- Auteurs : KHAN I. M.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Experimental study of vortex diffusers.
- Auteurs : SHAKERIN S., MILLER P. L.
- Date : 23/06/1996
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche
-
Performance of VAV fan-powered terminal units: ...
- Auteurs : FURR J. C., O'NEAL D. L., DAVIS M. A., et al.
- Date : 19/01/2008
- Langues : Anglais
- Source : ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.
Voir la fiche
-
Performance of VAV parallel fan-powered termina...
- Auteurs : FURR J. C., O'NEAL D. L., DAVIS M. A., et al.
- Date : 19/01/2008
- Langues : Anglais
- Source : ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.
Voir la fiche
-
Performance of VAV series fan-powered terminal ...
- Auteurs : FURR J. C., O'NEAL D. L., DAVIS M. A., et al.
- Date : 19/01/2008
- Langues : Anglais
- Source : ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.