Régulation de diffuseur d'air variable à vortex sans consommation supplémentaire d'énergie .
Regulacija varijabilnog vrtloznog difuzora bez pomoci dodatne energije./ Variable vortex diffuser control without additional energy.
Auteurs : ZGAVEC D.
Résumé
Up to date and functional equipment for the affordable price is the objective of all air conditioning system investments. The new type of regulation, developed in IMP Klima for the variable diffuser, meets this objective. Regulation is based on the well-known thermostatic head principle. Thermostatic head piston movement is stepless transmitted into the angle of diffuser blades. The mechanism allows automatic angle adjustment between 30 and 75° in temperature range between 20 and 30°C. The whole range is not suitable for all ventilation modes, therefore double regulation in added to the mechanism. First regulation for the cooling mode allows limitation of the initial angle. Second regulation for the heating mode allows limitation of the final angle. The advantage of the new regulation system is automatic adaptation of the blade angle to the inlet air temperature without the need for additional power supply, which eliminates the need for an additional installation.
Détails
- Titre original : Regulacija varijabilnog vrtloznog difuzora bez pomoci dodatne energije./ Variable vortex diffuser control without additional energy.
- Identifiant de la fiche : 2007-0297
- Langues : Serbe
- Source : Zbornik radova pisanih za 36. kongres o klimatizaciji, grejanju, hladenju + CD-ROM./ Proceedings of the 36th International HVAC&R congress + CD-ROM.
- Date d'édition : 02/11/2005
Liens
Voir d'autres communications du même compte rendu (19)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Autres équipements de conditionnement d'air
- Mots-clés : Ventilateur; Conception; Régulation; Diffuseur d'air; Débit; Conditionnement d'air
-
Detailed measurements of airflow characteristic...
- Auteurs : CHUAH Y. K., HU S. C., BARBER J. M.
- Date : 09/07/2000
- Langues : Anglais
- Source : Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
Voir la fiche
-
A performance evaluation of the HVAC-based nozz...
- Auteurs : KHAN I. M.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Terminal form and application choice of cold ai...
- Auteurs : LI L., ZHANG J.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Performance and application of induction diffuser.
- Auteurs : QU Y. X., ZHANG L. H.
- Date : 09/09/1997
- Langues : Anglais
- Source : International Symposium on Air Conditioning in High Rise Buildings - 1997
- Formats : PDF
Voir la fiche
-
Experimental determination of the performance o...
- Auteurs : KENYON A. E., KIRKPATRICK A. T.
- Date : 1998
- Langues : Anglais
- Source : ASHRAE Transactions. 1998 Winter Meeting, San Francisco, CA.