Méthodes pour estimer la vitesse de ventilation nécessaire dans les parkings souterrains.
[In Japanese. / En japonais.]
Auteurs : YOSHINO H., KONDO Y.
Type d'article : Article
Résumé
In underground car parks, vehicles emit exhaust gases, including carbon monoxide (hereafter CO) etc. Underground car parks are usually mechanically ventilated because they are enclosed with walls, etc. and there are not enough effective openings for natural ventilation. In such large enclosures containing contaminant sources, it is important to supply fresh air for the occupied zone and to remove polluted air efficiently. In the paper, the acceptable concentration of CO and the required ventilation rate for a car park in Japan were compared with those in other countries. The pollutant emission rate from vehicles was decreased by recent emission regulations. The CO emission volume was estimated by the amount of time vehicles travelled according to the sizes of car parks and the frequency of entering/exiting vehicles. The procedure to estimate the CO emission volume and the required ventilation rate was demonstrated using several charts.
Détails
- Titre original : [In Japanese. / En japonais.]
- Identifiant de la fiche : 2005-0392
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 93
- Date d'édition : 04/2004
Liens
Voir d'autres articles du même numéro (3)
Voir la source
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Japon; Automobile; Calcul; Ventilation; Air; Entrepôt souterrain; Débit
-
Régulation du volume d'air variable des termina...
- Auteurs : ZHU Z., HE Y.
- Date : 06/2008
- Langues : Chinois
- Source : HV & AC - vol. 38 - n. 6
- Formats : PDF
Voir la fiche
-
Standard 62's multiple spaces equation: for des...
- Auteurs : KETTLER J.
- Date : 08/2003
- Langues : Anglais
- Source : ASHRAE Journal - vol. 45 - n. 8
Voir la fiche
-
Discussion sur un système de conditionnement d'...
- Auteurs : ZHONG X.
- Date : 12/2012
- Langues : Chinois
- Source : HV & AC - vol. 42 - n. 272
- Formats : PDF
Voir la fiche
-
VAV AND CONSTANT-VOLUME SYSTEMS: A TIME AND PLA...
- Auteurs : ROUNTREE H. E.
- Date : 01/1991
- Langues : Anglais
- Source : Consult. Specif. Eng. - vol. 9 - n. 1
Voir la fiche
-
Prévision de l'écoulement d'air et de l'environ...
- Auteurs : FUKUYO K., SHIMODA Y., MIZUNO M.
- Date : 04/1996
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 61
Voir la fiche