Document IIF

Migration du frigorigène et modification de la viscosité de l’huile du carter d’un compresseur rotatif haute pression au R290 pendant le processus d’arrêt. 

Refrigerant migration and oil sump viscosity change of R290 high-pressure rotary compressor during shutdown process.

Auteurs : LEI B., WANG C., DUAN J., DU Y., WU J., LI X.

Type d'article : Article de la RIF

Résumé

Propane (R290) has excellent thermophysical properties and development potential. The dynamic characteristics of R290 rotary compressors and room air conditioners have been studied mainly on the start-up and defrost processes. There is little research on the shutdown process. Unlike hydrofluorocarbons (HFCs), the density of liquid propane is lower than that of lubricant. It is difficult for propane to dissolve into the oil sump and downward after the refrigerant separation after shutdown. The shutdown state affects the distribution of refrigerant in the oil sump and the mixture viscosity of the restart-up, which is related to the compressor reliability. In this paper, an R290 room air conditioner system was built and the variations of system pressures, temperatures, and oil sump parameters of an R290 high-pressure rotary compressor with three different lubricants were measured after shutdown in two conditions. As the experiments indicated, driven by the refrigerant supersaturation (the difference between the actual refrigerant solubility and saturation solubility) resulting from the rapid pressure drop after shutdown, a large amount of refrigerant separated from the oil sump, and the refrigerant solubility dropped fast. As the compressor temperature decreased, the bottom viscosity reached a peak. For the low-temperature heating condition, the peak was about 120.4~160.1mPa•s. However, when the degree of supersaturation decreased to a certain value, the refrigerant no longer separated out. There is always a solubility gradient of refrigerant in the oil sump of R290 high-pressure compressor after shutdown. Its size was related to the pressure drop and the miscibility of lubricants and refrigerants.

Documents disponibles

Format PDF

Pages : 8 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Refrigerant migration and oil sump viscosity change of R290 high-pressure rotary compressor during shutdown process.
  • Identifiant de la fiche : 30029441
  • Langues : Anglais
  • Sujet : Technologie
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 136
  • Date d'édition : 04/2022
  • DOI : http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2022.01.021
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres articles du même numéro (23)
Voir la source