Document IIF
Minimiser la collecte de données pour la calibration du champ de capteurs virtuels à régime permanent pour les équipements HVAC.
Minimizing data collection for field calibration of steady-state virtual sensors for HVAC equipment.
Auteurs : CHEUNG H., BRAUN J. E.
Type d'article : Article, Article de la RIF
Résumé
The paper presents an algorithm to minimize the amount of data collection for calibration of steady-state virtual sensors when obtained during normal operation of HVAC equipment in the field. If virtual sensors were calibrated using laboratory data, the amount of the calibration data could be minimized using design of experiment techniques. However, these techniques are not applicable to data from field operating equipment since most of the operating conditions are not controllable (e.g., ambient temperature, loads). In this paper, an algorithm to minimize the data collection period for calibration of steady-state virtual sensors is developed based on sensor accuracy, reliability and applicability. Application of the method is demonstrated for calibration of hourly electricity consumption virtual sensors for 3 packaged air conditioners that are serving a small commercial building, and the method terminated the calibration process after about 3 weeks of data collection for all units with very accurate estimates of electricity consumption.
Documents disponibles
Format PDF
Pages : 96-105
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Minimizing data collection for field calibration of steady-state virtual sensors for HVAC equipment.
- Identifiant de la fiche : 30018475
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 69
- Date d'édition : 09/2016
Liens
Voir d'autres articles du même numéro (37)
Voir la source
Indexation
-
Transient humidity measurements for flow throug...
- Auteurs : WANG Y. H., BESANT R. W., SIMONSON C. J., et al.
- Date : 2005
- Langues : Anglais
- Source : ASHRAE Transactions. 2005 Annual Meeting, Denver, Colorado, USA. Volume 111, part 2 + CD-ROM.
Voir la fiche
-
ANALYSE DE L'ECOULEMENT EN REGIME PERMANENT DAN...
- Auteurs : TSUSHIMA T., MORIKAWA Y.
- Date : 1985
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 28
Voir la fiche
-
A study on fractal fluctuation characteristics ...
- Auteurs : ZHANG P., WU Y. Y., XU Y. X., et al.
- Date : 22/04/2003
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
Voir la fiche
-
Wassersystem für gleichzeitiges Heizen und Kühlen.
- Date : 21/10/2005
- Langues : Allemand
- Source : CCI.Print - vol. 39 - n. 12
Voir la fiche
-
Variable-air-volume terminal units. I. Steady-s...
- Auteurs : KHOO I., LEVERMORE G. J., LETHERMAN K. M.
- Date : 1998
- Langues : Anglais
- Source : Build. Serv. Eng. Res. Technol. - vol. 19 - n. 3
Voir la fiche