IIR document
Minimizing data collection for field calibration of steady-state virtual sensors for HVAC equipment.
Author(s) : CHEUNG H., BRAUN J. E.
Type of article: Article, IJR article
Summary
The paper presents an algorithm to minimize the amount of data collection for calibration of steady-state virtual sensors when obtained during normal operation of HVAC equipment in the field. If virtual sensors were calibrated using laboratory data, the amount of the calibration data could be minimized using design of experiment techniques. However, these techniques are not applicable to data from field operating equipment since most of the operating conditions are not controllable (e.g., ambient temperature, loads). In this paper, an algorithm to minimize the data collection period for calibration of steady-state virtual sensors is developed based on sensor accuracy, reliability and applicability. Application of the method is demonstrated for calibration of hourly electricity consumption virtual sensors for 3 packaged air conditioners that are serving a small commercial building, and the method terminated the calibration process after about 3 weeks of data collection for all units with very accurate estimates of electricity consumption.
Available documents
Format PDF
Pages: 96-105
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Minimizing data collection for field calibration of steady-state virtual sensors for HVAC equipment.
- Record ID : 30018475
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 69
- Publication date: 2016/09
Links
See other articles in this issue (37)
See the source
Indexing
-
Themes:
Other air-conditioning equipment;
Thermodynamic measurements - Keywords: Sensor; Calibration; Design; Steady state; Accuracy; Air conditioning
-
ANALYSIS OF STEADY FLOW IN PIPING NETWORK. THE ...
- Author(s) : TSUSHIMA T., MORIKAWA Y.
- Date : 1985
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 28
View record
-
Wassersystem für gleichzeitiges Heizen und Kühlen.
- Date : 2005/10/21
- Languages : German
- Source: CCI.Print - vol. 39 - n. 12
View record
-
The transient response of capacitive thin-film ...
- Author(s) : DOOLEY J. B., O'NEAL D. L.
- Date : 2008/09
- Languages : English
- Source: HVAC&R Research - vol. 14 - n. 5
View record
-
Variable-air-volume terminal units. I. Steady-s...
- Author(s) : KHOO I., LEVERMORE G. J., LETHERMAN K. M.
- Date : 1998
- Languages : English
- Source: Build. Serv. Eng. Res. Technol. - vol. 19 - n. 3
View record
-
Air handling: go with the flow.
- Author(s) : VOGT J.
- Date : 2008/06
- Languages : English
- Source: Build. Serv. J. - vol. 30 - n. 6
View record