Minimizing data collection for field calibration of steady-state virtual sensors for HVAC equipment.
Author(s) : CHEUNG H., BRAUN J. E.
Type of article: Article, IJR article
Summary
The paper presents an algorithm to minimize the amount of data collection for calibration of steady-state virtual sensors when obtained during normal operation of HVAC equipment in the field. If virtual sensors were calibrated using laboratory data, the amount of the calibration data could be minimized using design of experiment techniques. However, these techniques are not applicable to data from field operating equipment since most of the operating conditions are not controllable (e.g., ambient temperature, loads). In this paper, an algorithm to minimize the data collection period for calibration of steady-state virtual sensors is developed based on sensor accuracy, reliability and applicability. Application of the method is demonstrated for calibration of hourly electricity consumption virtual sensors for 3 packaged air conditioners that are serving a small commercial building, and the method terminated the calibration process after about 3 weeks of data collection for all units with very accurate estimates of electricity consumption.
Available documents
Format PDF
Pages: 96-105
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Minimizing data collection for field calibration of steady-state virtual sensors for HVAC equipment.
- Record ID : 30018475
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 69
- Publication date: 2016/09
Links
See other articles in this issue (37)
See the source
Indexing
-
Themes:
Other air-conditioning equipment;
Thermodynamic measurements - Keywords: Sensor; Calibration; Design; Steady state; Accuracy; Air conditioning
-
A study on fractal fluctuation characteristics ...
- Author(s) : ZHANG P., WU Y. Y., XU Y. X., et al.
- Date : 2003/04/22
- Languages : English
- Source: Cryogenics and refrigeration. Proceedings of ICCR 2003.
View record
-
An improved virtual calibration of a supply air...
- Author(s) : YU D., LI H., NI L., et al.
- Date : 2011/10
- Languages : English
- Source: HVAC&R Research - vol. 17 - n. 5
View record
-
Virtual calibration of a supply air temperature...
- Author(s) : YU D., LI H., YU Y., et al.
- Date : 2011/02
- Languages : English
- Source: HVAC&R Research - vol. 17 - n. 1
View record
-
Transient humidity measurements for flow throug...
- Author(s) : WANG Y. H., BESANT R. W., SIMONSON C. J., et al.
- Date : 2005
- Languages : English
- Source: ASHRAE Transactions. 2005 Annual Meeting, Denver, Colorado, USA. Volume 111, part 2 + CD-ROM.
View record
-
Economic uncertainties in chilled water system ...
- Author(s) : KAMMERUD R., GILLESPIE K. L., HYDEMAN P. E.
- Date : 1999
- Languages : English
- Source: ASHRAE Transactions. 1999 Annual Meeting, Seattle, Washington + CD-ROM.
View record