Mise au point d'un cryoréfrigérateur à tube à pulsation, multidérivation, coaxial, à haute fréquence, inférieur à 14 K.

Development of a high-frequency coaxial multi-bypass pulse tube refrigerator below 14 K.

Auteurs : ZHOU Q., CHEN L., ZHU X., et al.

Type d'article : Article

Résumé

A high-frequency coaxial multi-bypass pulse tube refrigerator (MBPTR) was designed, manufactured, and tested. The cold finger is driven by a linear compressor through a connection tube to reduce the vibrations coming from the compressor. The pulse tube refrigerator adopts a coaxial configuration with a double- inlet and a single multi-bypass to improve the performance. With Er3Ni spheres at the cold end of the regenerator, the refrigerator can reach a no-load temperature of 13.9 K with 250W electric input power, which is the lowest temperature for this kind of refrigerator reported so far. Especially, the interplay of double-inlet and multi-bypass was observed experimentally. An Er3Ni spheres regenerator was found to be a potential substitution for stainless steel wire mesh (SSWM) regenerator for this kind of refrigerator.

Détails

  • Titre original : Development of a high-frequency coaxial multi-bypass pulse tube refrigerator below 14 K.
  • Identifiant de la fiche : 30014450
  • Langues : Anglais
  • Source : Cryogenics - vol. 67
  • Date d'édition : 04/2015
  • DOI : http://dx.doi.org/10.1016/j.cryogenics.2015.01.006

Liens


Voir d'autres articles du même numéro (8)
Voir la source