MISE AU POINT DE GROUPES FRIGORIFIQUES A ABSORPTION POUR L'ENTREPOSAGE FRIGORIFIQUE DES PRODUITS AGRICOLES.

DEVELOPMENT OF ABSORPTION REFRIGERATION UNITS FOR COLD STORAGE OF AGRICULTURAL PRODUCTS.

Auteurs : BORDE I., JELINEK M.

Résumé

L'UTILISATION DE R22 ET DE SYSTEMES DE SOLVANTS ORGANIQUES APPROPRIES EST SOUHAITABLE DANS LES INSTALLATIONS FRIGORIFIQUES A ABSORPTION. POUR LE R22 ON A MESURE LES RELATIONS DE L'EQUILIBRE VAPEUR-LIQUIDE SUR UNE PLAGE ETENDUE DE PRESSIONS, DE TEMPERATURES ET DE CONCENTRATIONS. UN CHOIX RATIONNEL DES COMBINAISONS OPTIMALES A ETE OPERE EN S'APPUYANT SUR LES RESULTATS GLOBAUX OBTENUS A PARTIR D'UN MODELE DE SIMULATION PAR ORDINATEUR. UN CYCLE A ETE CONSTRUITPOUR LES PAIRES CHOISIES DE FRIGORIGENE-ABSORBANT. LES CONDITIONS DE FONCTIONNEMENT OPTIMALES SONT DETERMINEES. LA STABILITE DE FONCTIONNEMENT EST OBTENUE PAR L'UTILISATION DANS CETTE PLAGE, DANS LAQUELLE LE COP ET LE TAUX DE CIRCULATIONSONT RELATIVEMENT CONSTANTS. D'APRES LES RECHERCHES EFFECTUEES ON A CONSTRUIT UN PROTOTYPE DE GROUPE FRIGORIFIQUE NOUVEAU D'ENVIRON 53 KILOW. IL FONCTIONNE A 270 K (-3 DEG C) ET MAINTIENT LA CHAMBRE D'ENTREPOSAGE A 278 K (5 DEG C). DE L'EAU CHAUDE REFROIDISSEMENT EST A 299 K (26 DEG C).

Détails

  • Titre original : DEVELOPMENT OF ABSORPTION REFRIGERATION UNITS FOR COLD STORAGE OF AGRICULTURAL PRODUCTS.
  • Identifiant de la fiche : 1987-1334
  • Langues : Anglais
  • Date d'édition : 14/04/1986
  • Source : Source : Frigair '86, Pretoria
    vol. 2; n. 23; 5 p.; 4 fig.; 3 ref.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.