Mise en œuvre d'un système de conditionnement d'air à déshydratant de type discontinu et évaluation de la performance pour une maison indépendante.
Implementation of batch type desiccant air-conditioning system for a detached house and performance evaluation.
Numéro : pap. 97
Auteurs : KOBAYASHI R., KATO S., HIYAMA K., et al.
Résumé
It is important to remove excess humidity that causes a decrease in indoor air quality (IAQ) in detached houses. One possible method discussed for removing this excess humidity is desiccant air-conditioning. However, there is a lack of existing examples of installed desiccant air-conditioning systems for detached houses. Thus, the motivation of this study is the development of a batch-type desiccant air-conditioning system for a detached house. We installed a prototype system in a detached house in Sapporo Japan in 2011. The system has two silica gel tanks with cooling and heating coils in each. One tank is used for air-conditioning while the other tank is used for the regeneration of its silica gel. We switched the role of the two desiccant tanks on a controlled schedule. This proposed system has two operating modes: dehumidification-cooling and humidification-heating. We carried out two experiments to check the basic performance of this system in different outdoor conditions (summer and winter). The summer experiment confirmed that it was possible to dehumidify air ~ 8 g/kg (DA) in high humidity outdoor air. In addition, the cold water recovered adsorption heat under these conditions. The winter experiment confirmed that the system worked as a heating unit and humidifier without a water-supply pipe with ~25% of sensible heat supplied into the desiccant tanks by the heating coil changed to latent heat.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Implementation of batch type desiccant air-conditioning system for a detached house and performance evaluation.
- Identifiant de la fiche : 30008601
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
-
PREDICTING THE PERFORMANCE OF MOLECULAR SIEVE R...
- Auteurs : RUSH W. F., WURM J.
- Date : 10/08/1991
- Langues : Anglais
- Source : New challenges in refrigeration. Proceedings of the XVIIIth International Congress of Refrigeration, August 10-17, 1991, Montreal, Quebec, Canada.
- Formats : PDF
Voir la fiche
-
A new configuration of the desiccant dehumidifi...
- Auteurs : KABEEL A. E., ABDELGAIED M.
- Date : 07/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 103
- Formats : PDF
Voir la fiche
-
Desiccant solar air conditioning in tropical cl...
- Auteurs : DUPONT M., CELESTINE B., BEGHIN B.
- Date : 1994
- Langues : Anglais
- Source : Int. J. sol. Energy - vol. 52 - n. 6
Voir la fiche
-
Numerical and experimental analysis of desiccan...
- Auteurs : ABISHRAJ V. R., GURUBALAN A., MAIYA M. P., SIMONSON C.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
DESICCANT COOLING RESEARCH AND DEVELOPMENT IN J...
- Auteurs : MATSUKI K., SAITO Y.
- Date : 1988
- Langues : Anglais
Voir la fiche