A steady state description of the thermal pump driving the Diffusion Absorption Refrigerator was integrated in the model previously proposed by the same authors. The thermal pump allows the DAR cycle to be activated, moving the strong mixture and separating the refrigerant from the weak one. So, the design parameters play a primary role in the DAR cycle performance in terms of COP. The enhanced model results were validated on a prototype built coupling a domestic 750 W-magnetron on a small purposely modified commercial DAR to activate the thermal pump. A maximum mismatch of 2.32% in the weak mixture mass flow rate and lower than 5% in COP between the predicted and measured data were found. The microwaves activated thermal pump produced a distinct reduction in the starting transient time of the refrigerator and for this reason it can be proposed as a valid candidate to be used as a rapid cooler in small refrigeration applications.

Documents disponibles

Format PDF

Pages : 1495-1503

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : An enhanced model for the design of diffusion absorption refrigerators.
  • Identifiant de la fiche : 30008140
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 5
  • Date d'édition : 08/2013

Liens


Voir d'autres articles du même numéro (16)
Voir la source