Document IIF
Modèle théorique pour calculer les performances des frigorigènes à base de HFO dans les systèmes simples à évaporateur noyé.
Theoretical model for calculating HFO based refrigerant performance in simple flooded evaporator systems.
Numéro : pap. n. 1121
Auteurs : ROBERTS N. A., SIMONI L. D.
Résumé
Over the last 30 years regulations have been implemented globally focusing on the environmental impact of refrigerants and equipment. Throughout the transition from CFCs to HFCs, and now the need to change again to HFOs, there has been one type of equipment design that has always been seen as a problem and often the last to be retrofitted or replaced, the flooded evaporator system.
Flooded evaporator systems are often bespoke designs making a retrofit option financially more attractive. Often the replacement offered for the incumbent refrigerant (which typically has no or very low temperature glide) was primarily for the direct expansion market and has a significant temperature glide which potentially introduces additional complications and performance issues.
This paper is an initial step into producing a model to predict performance when using low GWP HFO based blends to replace HFCs in simple designs of three types of flooded evaporator systems, i.e. liquid overfeed system, pumped circulation system and simple shell and tube flooded evaporator system.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Theoretical model for calculating HFO based refrigerant performance in simple flooded evaporator systems.
- Identifiant de la fiche : 30024825
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Date d'édition : 09/2018
- DOI : http://dx.doi.org/10.18462/iir.hfo.2018.1121
Liens
- Voir aussi : Theoretical model for calculating HFO based refrigerant performance in simple flooded evaporator systems.
Voir d'autres communications du même compte rendu (126)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Evaporateurs, condenseurs et autres échangeurs thermiques;
HFC - Mots-clés : Évaporateur noyé; R452A; R449A; Propriété thermodynamique; Prévision; Performance; Modélisation; HFO
-
Theoretical model for calculating HFO based ref...
- Auteurs : ROBERTS N. A., SIMONI L. D.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Application of an HFO blend (R-449A) in flooded...
- Auteurs : SNYDER D., ALLGOOD C., PANSULLA A.
- Date : 06/2021
- Langues : Anglais
- Source : 2nd IIR Conference on HFO Refrigerants and Low GWP Blends
- Formats : PDF
Voir la fiche
-
Flow boiling heat transfer of zeotropic mixture...
- Auteurs : XIA Y., YU J., SUULKER D., WANG H. S.
- Date : 06/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 150
- Formats : PDF
Voir la fiche
-
Thermo-economic analysis of low Global Warming ...
- Auteurs : CITARELLA B., MASTRULLO R., MAURO A. W., SFRAGARA M., TAMMARO M.
- Date : 26/08/2020
- Langues : Anglais
- Source : 6th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Nantes, France, August 26-28 2020
- Formats : PDF
Voir la fiche
-
Frost growth and densification on flat surfaces.
- Auteurs : CHEIKH A. el, JACOBI A.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF