Document IIF

Modèle théorique pour un cryorefroidisseur à tube à éjecteur de type Gifford-McMahon.

Theoretical model for GM type orifice pulse tube cryocooler.

Résumé

In the paper, a theoretical model for analysis of GM (Gifford-McMahon) type orifice of pulse tube cryocooler has been developed. The model includes the calculation of ideal refrigeration power, various losses viz. regenerator losses, heat conduction losses etc. and net refrigeration power for known input of pressure pulse and other parameters. Effect of orifice opening, frequency and pressures on the performance of GM type pulse tube cryocooler is predicted. The results obtained are compared with those available in the literature and are found to be in good qualitative and quantitative agreement. Hence the model developed can be used for the design of a GM type of pulse tube cryocooler.

Documents disponibles

Format PDF

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Theoretical model for GM type orifice pulse tube cryocooler.
  • Identifiant de la fiche : 2004-2078
  • Langues : Anglais
  • Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
  • Date d'édition : 17/08/2003

Liens


Voir d'autres communications du même compte rendu (398)
Voir le compte rendu de la conférence