Document IIF

Modèle unidimensionnel utilisé pour prévoir la performance d'un éjecteur sous des conditions de fonctionnement critiques et sous-critiques.

A 1D model to predict ejector performance at critical and sub-critical operational regimes.

Auteurs : CHEN W., LIU M., CHONG D., et al.

Type d'article : Article, Article de la RIF

Résumé

This paper proposes a new 1D model to predict ejector performance at critical and sub-critical operational modes, while most previous 1D models have only predicted ejector performance at critical mode operation. Constant pressure mixing is assumed to occur inside the constant area section of the ejector at critical and sub-critical mode operation, and the effectiveness of the model is verified against four sets of experimental data that include different working fluids and geometries. The results show that the proposed model accurately predicts ejector performance over all ranges of operation, and is a useful tool for predicting ejector performance within larger refrigeration cycle models.

Documents disponibles

Format PDF

Pages : 1750-1761

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : A 1D model to predict ejector performance at critical and sub-critical operational regimes.
  • Identifiant de la fiche : 30008706
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 6
  • Date d'édition : 09/2013

Liens


Voir d'autres articles du même numéro (17)
Voir la source