Résumé

This article presents a model to predict refrigerant flow rate through the bleed port of a thermostatic expansion valve using a separated flow model. Four types of inlet/outlet conditions: liquid/liquid; liquid/two-phase; two-phase/two-phase; and vapour/vapour are studied. Refrigerant flow rate predictions of the model are compared to measured data. The results of this comparison show that the model is within plus or minus 20% for 95% of the experimental data corresponding to either an inlet fluid in a subcooled or a two-phase state. When the inlet fluid is in a vapour state, the model is able to predict 96% of the experimental data within plus or minus 16%.

Documents disponibles

Format PDF

Pages : 826-836

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Modelling the bleed port of a thermostatic expansion valve.
  • Identifiant de la fiche : 2009-1538
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 5
  • Date d'édition : 08/2009

Liens


Voir d'autres articles du même numéro (38)