This article reports on the development of a mathematical model for a finned tube condenser, which is a part of the heat exchanger in a heat-pump tumble dryer. The purpose of this model was to determine the number of tube rows with respect to the minimal mass and volume of the condenser, while maintaining the energy efficiency. The analysis was based on the ?-NTU method, which was further evaluated by the experimental data obtained from measurements performed on a commercial heat-pump tumble dryer. The model can be broadly used for different geometries, refrigerants and air velocities to evaluate the condenser’s performance. The numerical results show good agreement with the experimental data; the difference between the predicted and measured outlet air temperatures being less than 4.5%. According to the numerical results, a new condenser, with a 28.5% reduction in the initial size, was designed and tested.

Documents disponibles

Format PDF

Pages : 8

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Modelling and experimental evaluation of a condenser for a heat-pump tumble dryer.
  • Identifiant de la fiche : 30026472
  • Langues : Anglais
  • Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
  • Date d'édition : 24/08/2019
  • DOI : http://dx.doi.org/10.18462/iir.icr.2019.0732

Liens


Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence