Document IIF

Modélisation numérique et analyse des performances saisonnières des pompes à chaleur air-eau fonctionnant au frigorigène R-454B à faible PRP comme alternative au R-410A.

Numerical modelling and seasonal performance analysis of air-to- water heat pumps using low-gwp refrigerant R-454B as an alternative to R-410A.

Numéro : 1920

Auteurs : DONGELLINI M., NALDI C., SIANI R., MORINI G. L.

Résumé

In this paper, a numerical model for air-to-water heat pumps is presented and validated with experimental data. The model is used with the aim to test the differences, in terms of seasonal energy performances, obtained by using the low-GWP refrigerant R-454B as alternative to R-410A. Each component of the heat pump (i.e. compressor, heat exchangers, fans, expansion valve) is modelled and its thermodynamic performance is evaluated following nested iterative cycles. Different configurations of the heat pump have been simulated. Results confirm that R-454B is a valid alternative to R-410A. An increase of the heat pump seasonal energy efficiency ratio (SEER) up to 2.5% can be obtained with the low-GWP refrigerant.

Documents disponibles

Format PDF

Pages : 8

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Numerical modelling and seasonal performance analysis of air-to- water heat pumps using low-gwp refrigerant R-454B as an alternative to R-410A.
  • Identifiant de la fiche : 30028898
  • Langues : Anglais
  • Sujet : Alternatives aux HFC
  • Source : 6th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
  • Date d'édition : 01/09/2021
  • DOI : http://dx.doi.org/10.18462/iir.TPTPR.2021.1920
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (48)
Voir le compte rendu de la conférence