Modélisation numérique pour l'adaptation des tubes capillaires adiabatiques hélicoïdaux dans un conditionneur d'air split utilisant le HCFC-22 et le HC-290.
Numerical model for matching of coiled adiabatic capillary tubes in a split air conditioner using HCFC-22 and HC-290.
Résumé
This work presents a simple model for matching coiled capillary tubes and the refrigerant charge in a split air conditioner when the other components are fixed. The system model is composed of sub-models for the key components, i.e., a lumped model for the compressor, zone models for the condenser and the evaporator, and a four flow region distributed model for the coiled adiabatic capillary tube in series with the liquid tube. The C-M-N method is employed to calculate the friction factors in the coiled capillary tube. HCFC-22 and HC-290 are used for the simulations. The comparison of the model prediction with experimental data shows the errors are less than ±5% except for the mass flow rate with a maximum deviation of 8.63%. The results confirm that both the cooling capacity and input power are slightly reduced when HCFC-22 is replaced by HC-290 with the coiled capillary tube and refrigerant charge matched to the HC290 refrigerant. The results also show that when coil diameter is reduced from 0.3 m to 0.04 m, the capillary tube length is reduced by about 10% for both HCFC-22 and HC-290. This model can be used to design components for small air conditioning systems using HCFC22 and HC290. [Reprinted with permission from Elsevier. Copyright, 2010].
Détails
- Titre original : Numerical model for matching of coiled adiabatic capillary tubes in a split air conditioner using HCFC-22 and HC-290.
- Identifiant de la fiche : 30001468
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 30 - n. 11-12
- Date d'édition : 08/2010
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2010.03.009
Liens
Voir d'autres articles du même numéro (6)
Voir la source
-
Experimental study on the failure of electronic...
- Auteurs : LI J., DU Y., WU J., LIN J., WANG C.
- Date : 04/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 112
- Formats : PDF
Voir la fiche
-
Use of peripheral fins for R-290 charge reducti...
- Auteurs : RIBEIRO G. B., BARBOSA J. Jr
- Date : 10/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Formats : PDF
Voir la fiche
-
Propane as refrigerant in a reversible split ty...
- Auteurs : ALOISI A.
- Date : 07/12/2000
- Langues : Anglais
- Source : The International Symposium on HCFC Alternative Refrigerants and Environmental Technology 2000: Latest technology for Energy Conservation, Refrigerants and Recycling on Air-Conditioning and Refrigeration Equipment for the 21st century. Proceedings.
Voir la fiche
-
Indoor leakage test for safety of R-290 split t...
- Auteurs : LI T.
- Date : 04/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 40
- Formats : PDF
Voir la fiche
-
Air-air split AC with minimum charge of propane.
- Auteurs : ANDERSON K., LUNDAHL G., GRANRYD E.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF