Document IIF

Modélisation théorique et validation expérimentale d’un réfrigérateur à absorption-diffusion de faible puissance.

Theoretical modeling and experimental validation of a small capacity diffusion-absorption refrigerator.

Auteurs : PÉREZ-GARCÍA V., RODRíGUEZ-MUÑOZ J. L., BELMAN-FLORES J. M., et al.

Type d'article : Article, Article de la RIF

Résumé

In this paper, an alternative global model of a small commercial diffusion-absorption refrigerator to pre- dict the outlet temperatures of each component, the liquid and vapor mass flow for the bubble pump and COP of the system is presented and compared with the experimental results. The model requires as input parameters: the thermal conditions (based on thermostat positions), the geometrical parameters and the ambient temperature. The results are displayed for seven different thermostat positions, where the tem- perature predictions indicate that the main components of the system have a deviation lesser than ±4 K. In the case of COP, the maximum relative error is 8% compared with experimental results.

Documents disponibles

Format PDF

Pages : 302-310

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Theoretical modeling and experimental validation of a small capacity diffusion-absorption refrigerator.
  • Identifiant de la fiche : 30026589
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
  • Date d'édition : 08/2019
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2019.05.014

Liens


Voir d'autres articles du même numéro (50)
Voir la source