Nouveau système de refroidissement évaporatif indirect pour éviter la formation de gel dans une tour de refroidissement utilisée dans les systèmes de centres de données.
A novel indirect evaporative chiller system to realize anti-freezing of cooling tower used in data centre systems.
Résumé
Data Centres have been developed quickly in recent years. For water cooled data centre cooling system, the freezing of cooling tower in winter is a big problem and very hard to solve. In this paper, a novel system using indirect evaporative chillers to solve the freezing problem is put forward. The running mode and the switch point from refrigeration to free cooling is discussed for the new system. The performance of the recommended system in both winter and summer conditions is analysed both by simulation and by field testing. Upon the results, the ice problem can be solved thoroughly in winter, and the out water temperature of the indirect evaporative chiller can be 6~9K lower than common cooling towers in summer. From a real case study, compared with common water-cooled systems, the free cooling time can be 1000 hours increase and the electricity consumption can be 30~60% reduced.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A novel indirect evaporative chiller system to realize anti-freezing of cooling tower used in data centre systems.
- Identifiant de la fiche : 30026799
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.1709
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
Indexation
-
ASPECTS OF ENERGY MINIMIZATION IN WATER CHILLER...
- Auteurs : BREDA-SMITH M. van
- Date : 14/04/1986
- Langues : Anglais
Voir la fiche
-
An integrated chiller using magnetic-bearing co...
- Auteurs : ZHANG P., SHI W., WANG B., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
FREE COMPUTER FACILITY CHILLING WITH A NONCONTA...
- Auteurs : BECKER H. P.
- Date : 1981
- Langues : Anglais
Voir la fiche
-
ANALYSIS OF COOLING TOWER PERFORMANCE ENHANCEMENT.
- Auteurs : SCALABRIN G.
- Date : 24/08/1987
- Langues : Anglais
- Source : Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Evaporative cooling choices to maximize watersi...
- Auteurs : LANE J., CLINE D.
- Date : 19/01/2008
- Langues : Anglais
- Source : ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.
Voir la fiche