Document IIF

Optimisation dans les agencements de passes pour les condenseurs à micro-canaux de pompes utilisant l'isobutane.

Optimization of pass arrangements for microchannel heat pump condensers using isobutane.

Numéro : pap. 1147

Auteurs : MEHENDALE S. S., AUTE V., RADERMACHER R.

Résumé

Microchannel heat exchangers (MCHX) have seen increased application in heat pumps because they offer greater compactness, significant charge reduction, lower refrigerant pressure drop and lower airside fan power consumption compared to traditional round tube-plate fin heat exchangers. Employing MCHX condenser (MCC) as well as evaporator (MCE) in a heat pump system using natural refrigerants offers significant potential for cost reduction as well as environmentally benign operation. Typically, for a given tube and fin surface geometry and operating conditions, the system designer has the freedom to choose the correct circuit arrangement to optimize the heat exchanger capacity. Very few studies on the circuit optimization of isobutane (R600a) MCHX have appeared in the open literature. In this work, we present the results of a simulation study that explores the circuit optimization of a MCC used in a R600a heat pump. Two-, three-, and four-pass circuit arrangements in expanding, contracting, and equal configurations were explored. The number of MCC tubes and the tube length were simultaneously varied so as to maintain a constant coil face area at a typical condenser operating condition in a residential heat pump. 36 tube x 0.562 m condenser coils are shown to provide the best heat duty among all possible contracting, expanding, and equal pass arrangements. The best contracting pass arrangement, 13-13-6-4, has about 27% higher heat duty compared to the worst pass arrangement, 28-26. The results are also explained based on the variations in refrigerant mass flow rate and enthalpy change among the various pass arrangements. The importance of designing coils with the optimal pass arrangement to maximize the heat duty is emphasized.

Documents disponibles

Format PDF

Pages : 8 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Optimization of pass arrangements for microchannel heat pump condensers using isobutane.
  • Identifiant de la fiche : 30019169
  • Langues : Anglais
  • Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
  • Date d'édition : 21/08/2016
  • DOI : http://dx.doi.org/10.18462/iir.gl.2016.1147

Liens


Voir d'autres communications du même compte rendu (140)
Voir le compte rendu de la conférence