Document IIF

Optimisation de la performance d'un réfrigérateur combiné de Carnot irréversible basée sur des critères écologiques.

Performance optimization of irreversible combined Carnot refrigerator based on ecological criterion.

Auteurs : FRIKHA S., ABID M. S.

Type d'article : Article, Article de la RIF

Résumé

This work presents a computational model based on exergy analysis for refrigeration cycles by taking the profit finite-time ecological optimization criterion as the objective. Firstly we investigate a generalized irreversible single refrigeration cycle with losses of heat leakage, internal irreversibility and external irreversibility, using this criterion. Then, we apply this study to a two-stage generalized irreversible combined refrigeration cycle. The optimal coefficient of performance (COP) and corresponding ecological function (E) of the combined cycle with respect to the two combined cycle design parameters (ß1 and ß2) are analyzed. This analysis identifies lower and upper bounds to the maximum ecological function and corresponding COP of the combined cycle. These results were compared with those of the single cycle. Finally we establish the optimal COP and maximum ecological function rational regions that define the design parameter limits of performed combined refrigeration cycles.

Documents disponibles

Format PDF

Pages : 153-165

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Performance optimization of irreversible combined Carnot refrigerator based on ecological criterion.
  • Identifiant de la fiche : 30016776
  • Langues : Anglais
  • Sujet : Environnement
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 62
  • Date d'édition : 02/2016

Liens


Voir d'autres articles du même numéro (17)
Voir la source