Optimisation du système de ventilation et de désodorisation d'une station d'épuration des eaux usées.
Ventilation and deodorization system optimization of a wastewater treatment plant.
Numéro : 187
Auteurs : CASACA C., HENRIQUES N., NUNES E. A. V., SIMOES T. A.
Résumé
Quality of life is entirely linked to air quality around us, whether inside or outside a building. Therefore, it is not surprising that the owners and occupants of certain spaces pay attention to the air quality, especially when they work or are close to a wastewater treatment plant. The aims of this work are to diagnose the existing situation in ventilation and deodorization system of covered wastewater treatment plant and to suggest changes to improve indoor air quality and make the operation of this system more reliable and economical. The ventilation system, consisting of 10 air handling units, supply 230.000 m3/h, where some ventilation lines have 250 m. The system’s optimization solution, as well as the two new centrifugal fans implementation, with speed variation, allow a reduction in the total fans power to 60 kW and increase the energy efficiency in 60 %.
Documents disponibles
Format PDF
Pages : 7
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Ventilation and deodorization system optimization of a wastewater treatment plant.
- Identifiant de la fiche : 30030535
- Langues : Afrikaans
- Source : XI Congreso Ibérico y IX Congreso Iberoamericano de Ciencias y Técnicas del Frío, CYTEF 2022.
- Date d'édition : 04/2022
Liens
Voir d'autres communications du même compte rendu (67)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Qualité de l'air intérieur
- Mots-clés : Qualité de l'air; Environnement intérieur; Ventilation; Odeur; Conditionnement d'air; Eau usée; Optimisation
-
Improving indoor air quality through the additi...
- Auteurs : KEMPSKI D. von, GOEPFERT A.
- Date : 04/1998
- Langues : Anglais
- Source : AIRAH J. - vol. 52 - n. 4
Voir la fiche
-
Perceived air quality: discussion on the new un...
- Auteurs : OSELAND N. A., RAW G. J.
- Date : 1993
- Langues : Anglais
- Source : Build. Serv. Eng. Res. Technol. - vol. 14 - n. 4
Voir la fiche
-
INDOOR AIR QUALITY IN BRUSSELS.
- Auteurs : APPLEBY P.
- Date : 11/1989
- Langues : Anglais
- Source : J. chart. Inst. Build. Serv. - vol. 11 - n. 11
Voir la fiche
-
Etude sur les odeurs en atmosphère intérieure.
- Auteurs : LI X. P., FAN C. Y.
- Date : 06/1996
- Langues : Chinois
- Source : HV & AC - vol. 26 - n. 112
Voir la fiche
-
Innovative features improve occupant satisfaction.
- Auteurs : OKAMOTO A., HASEGAWA T., TOGARI S.
- Date : 01/1993
- Langues : Anglais
- Source : S. A. Refrig. Aircond. - vol. 9 - n. 1
Voir la fiche