Optimisation environnementale de réseaux de chauffage urbain, avec pompes à chaleur centralisées ou décentralisées.
Optimización medioambiental de las redes de calefacción urbana con bombas de calor centralizadas o descentralizadas.
Auteurs : CURTI V., FAVRAT D., SPAKOVSKY M. R. von
Type d'article : Article
Résumé
This article presents the Spanish translation of the Bulletin of the IIR reference 1998-1934. In Switzerland like in many countries, many of the populated areas are located close to lakes or rivers, offering a large potential for the use of heat pumps. Although district heating is an obvious solution, adapting the delivery temperature to the most demanding users is detrimental to overall system performance. The best system configuration could avoid this pitfall by relying on a centralized plant of heat pumps with cogeneration, supplemented by decentralized heat pumps for the more demanding users. Modelling and optimization of such systems are developed. Results are shown for various user distributions and fuel and electricity prices. A comparison between the results found with and without taking into account pollution is also presented.
Détails
- Titre original : Optimización medioambiental de las redes de calefacción urbana con bombas de calor centralizadas o descentralizadas.
- Identifiant de la fiche : 2003-1575
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 29 - n. 331
- Date d'édition : 11/2001
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
- Voir les traductions : Environomic optimization of district heating network systems with both centralized and decentralized heat pumps.
Voir d'autres articles du même numéro (4)
Voir la source
-
Environomic optimization of district heating ne...
- Auteurs : CURTI V., FAVRAT D., SPAKOVSKY M. R. von
- Date : 01/09/1997
- Langues : Anglais
- Source : Heat Pump Systems, Energy Efficiency, and Global Warming.
- Formats : PDF
Voir la fiche
-
Case study on DHC system incorporating advanced...
- Auteurs : SUZUKI N., WATANABE K., UCHIDA T., HOSHII O., FUJIWARA M., IZAWA H., AKISAWA A., KASHIWAGI T.
- Date : 17/09/1996
- Langues : Anglais
- Source : Ab-sorption 96. Towards sustainable technologies. Proceedings./ Ab-sorption 96. Vers les technologies durables. Comptes rendus.
Voir la fiche
-
ECONOMIC DISTRIBUTION DISTANCE FOR COGENERATED ...
- Auteurs : PORTER R. W.
- Date : 07/1985
- Langues : Anglais
- Source : Far and Near in Water & Energy - vol. 10 - n. 7
Voir la fiche
-
Utilisation de l'eau du chauffage urbain pour l...
- Auteurs : MEBOLDT H.
- Date : 04/1993
- Langues : Allemand
- Source : Fernwärme int. - vol. 22 - n. 4
Voir la fiche
-
A successful combination: cogeneration and heat...
- Auteurs : EICHER H., WEILENMANN J.
- Date : 1996
- Langues : Anglais
- Source : IEA HPC Newsl. - vol. 14 - n. 1
Voir la fiche