Performance à charge partielle des refroidisseurs tout-ou-rien refroidis à l'air.
Part-load performance of on-off air-cooled chillers.
Auteurs : BENSAFI A., GAILLARD N., MORIN J. M.
Résumé
The nominal energy efficiency ratio as defined and measured under European Standard EN 14511 does not enable the performance characterization of a chiller under real usage conditions. This is because the rating conditions and methods do not take into account the changes in outdoor conditions and building load. In order to calculate the real air-conditioning system electricity consumption, part-load performance must therefore be accounted for. In 2006, Eurovent Certification implemented a certification scheme to calculate an European seasonal energy efficiency ratio (ESEER) for staged capacity chillers. In order to extend the ESEER concept to the residential application sector on a sound and fair basis, testing was conducted at CETIAT on small capacity air-cooled chillers. This paper shows the testing methodology and the results obtained on an on-off air-cooled chiller which was tested at 100, 75, 50 and 25% loads at 35, 30, 25 and 20°C outdoor conditions. The results from this exhaustive testing show in particular that the part-load energy efficiency can be related to full load efficiency at all outdoor temperatures following a unique relationship. This means that on-off chiller part-load performance can be predicted from a number of full-load tests and only a single part-load test measurements. Alternatively, as a less accurate and default method, stand-by power measurement can be used to calculate part-load performance during cycling.
Documents disponibles
Format PDF
Pages : ICR07-E1-882
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Part-load performance of on-off air-cooled chillers.
- Identifiant de la fiche : 2008-0343
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
-
Groupes d'eau glacée : le nouveau coefficient E...
- Date : 03/2007
- Langues : Français
- Source : Chaud Froid Plomb. - n. 699
Voir la fiche
-
Certification Eurovent de l'efficacité énergéti...
- Auteurs : SAHEB Y., RIVIERE P.
- Date : 10/2006
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - n. 1067
Voir la fiche
-
Maximizing chilled water plant efficiency.
- Auteurs : HO S.
- Date : 17/03/2005
- Langues : Anglais
- Source : Systems design approach for air conditioning conference. Thinking outside the flanges.
Voir la fiche
-
Optimizing chilled-water plant control.
- Auteurs : ZHOU G.
- Date : 06/2007
- Langues : Anglais
- Source : ASHRAE Journal - vol. 49 - n. 6
Voir la fiche
-
Real efficiencies of central plants: actual wir...
- Auteurs : ERPELDING B.
- Date : 05/2007
- Langues : Anglais
- Source : HPAC Engineering - vol. 79 - n. 5
Voir la fiche