Document IIF

Performance d'un réfrigérateur mixte gaz-azote pour le refroidissement d'amenées de courant (à 80 K).

Performance of a mixed gas-nitrogen-cascade refrigerator for 80 K current lead cooling.

Résumé

In the authors' earlier investigation, a system based on a nitrogen throttle cycle precooled by a mixed gas refrigerator was developed. The behaviour of this refrigeration system for forced flow vapour cooled current leads was simulated and verified experimentally. The performance of an improved nitrogen-mixed gas-cascade was recently estimated. The analysis of this system is given and compared with results of former investigations. Especially the advantage of a cascade refrigerator for "part load" operation is discussed.

Documents disponibles

Format PDF

Pages : 2004-1

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Performance of a mixed gas-nitrogen-cascade refrigerator for 80 K current lead cooling.
  • Identifiant de la fiche : 2005-1616
  • Langues : Anglais
  • Source : Cryogenics 2004. Proceedings of the 8th Cryogenics Conference
  • Date d'édition : 27/04/2004

Liens


Voir d'autres communications du même compte rendu (27)
Voir le compte rendu de la conférence