Résumé
The performances of the transcritical or subcritical cycle by using refrigerant mixtures of R32/R744 with mass fraction of 0/100, 5/95, 10/90, 20/80, 30/70, 40/60 and 50/50 were investigated. This experimental study attempts to verify the possibility of applying the new binary mixture in refrigeration systems and heat pumps. Performance evaluation had been carried out for a simple binary mixture R32/R744 transcritical or subcritical cycle by varying evaporator temperature. The results show that when evaporation temperature is 0°C, the discharge pressure are 5.59MPa and 4.86MPa with R32/R744 mass fraction of 40/60 and 50/50. Compared with pure R744, the discharge pressure reduces by 28.6% and 37.9% respectively. When evaporation temperature is 0°C, the input power of compressor is 1.0 kW and 1.28 kW with R32/R744 mass fraction of 40/60 and 50/50 respectively. Compared with pure R744, the input power of compressor reduces by 25.6% and 32.8% respectively. When evaporation temperature is -3°C, the COPh is 5.07 with R32/R744 mass fraction of 50/50 and reaches the maximum. Compared with pure R744, the COPh increases 20.4%. When evaporation temperature is -2°C, the COPc is 4.35 with R32/R744 mass fraction of 40/60 and reaches the maximum. Compared with pure R744, the COPc increases 20.8%. The water temperature of gas cooler reduces with the R32 ratio increases. When evaporation temperature is 0°C, the water temperature of gas cooler is 39.5°C, with R32/R744 mass fraction of 50/50. Compared with pure R744, the water temperature of gas cooler reduces by 7.3°C.
Documents disponibles
Format PDF
Pages : 11 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance of refrigeration & heat pump system by using binary mixtures of R32/R744.
- Identifiant de la fiche : 30013146
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Date d'édition : 02/08/2014
Liens
Voir d'autres communications du même compte rendu (119)
Voir le compte rendu de la conférence
-
Designing a CO2 heat pump satisfying...
- Auteurs : DELÊTRE P-J., KRISTOFERSSON J., HEERUP C., PEDERSEN T. S., LATVENAS A., KRISTOFFERSEN J. W., ANDERSEN H.
- Date : 08/2024
- Langues : Anglais
- Source : 16th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2024). Proceedings. University of Maryland, College Park, Maryland, USA, August 11-14 2024
- Formats : PDF
Voir la fiche
-
Natural refrigerant mixture alternatives retrof...
- Auteurs : TARLEA G., VINCERIUC M., ZABET I., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Energy-efficient heating and cooling systems fo...
- Auteurs : HALOZAN H., RIEBERER R.
- Date : 2004
- Langues : Français
- Source : IIF, Note Inf./IIR, Inf. Note/Bull. IIF-IIR/www.iifiir.org - vol. 84 - n. 6
- Formats : PDF
Voir la fiche
-
Experimental Setup and Test of a Desalination S...
- Auteurs : YANG S. K., SONG H. E., AHN Y. C.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche
-
Performance evaluation of CO2-based mixture ref...
- Auteurs : WU W., LEUNG M., LI X.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche