Performance d'une maison solaire de taille moyenne à énergie nette zéro.
Performance of a Mid-Size Net-Zero Energy Solar House.
Auteurs : TAHERIAN H., PETERS R. W.
Type d'article : Article de périodique
Résumé
The University of Alabama at Birmingham (UAB) was one of 16 collegiate teams from around the world that participated in the U.S. Department of Energy Solar Decathlon 2017 competition. An interdisciplinary team of students from across the university was engaged in a 2-year long process to design and build a house that is powered completely by solar power. The house was equipped to run all the typical appliances of an average modern house at similar levels on a conventional power grid. The net-zero house was built and tested on the UAB campus. Considering Birmingham’s weather, a safe room was built to ensure the safety of occupants during events of extreme weather, such as a tornado. A ductless HVAC unit consisting of an inverter-type 3-speed outdoor unit supplied refrigerant to four high-wall indoor units providing the primary source of space conditioning. To achieve a model of efficiency and cost effectiveness, the house incorporated a heavily insulated envelope and precise glazing protection. The roof, floor framing and walls had R-30 batt and foam insulation. With a design informed by southern vernacular language, the building is oriented to maximize solar access and to use roof planes for shading the majority of the year. Peak power generation of the panels was recorded at 9.6 kW. The home has a centralized energy management system that can provide access to energy consumption data and allow control of lighting, appliances, and plug loads remotely. Energy modeling showed that the annual electricity consumption for heating and cooling with variation in wall types were 8470 to 11,661 kWh. For the month of October, it was calculated varying from 683 to 763 kWh, with varying air changes per hour from 0 to 1.5.
Documents disponibles
Format PDF
Pages : 19 p.
Disponible
Gratuit
Détails
- Titre original : Performance of a Mid-Size Net-Zero Energy Solar House.
- Identifiant de la fiche : 30029584
- Langues : Anglais
- Sujet : Technologie
- Source : Applied Sciences - vol. 12 - n. 6
- Éditeurs : MDPI
- Date d'édition : 03/2022
- DOI : http://dx.doi.org/10.3390/app12063005
Liens
Voir d'autres articles du même numéro (4)
Voir la source
-
Study on renovation to solar houses with air co...
- Auteurs : UDAGAWA M., ROH H., KUSUNOKI T.
- Date : 18/09/2012
- Langues : Anglais
- Source : EuroSun 2012: solar energy for a brighter future. ISES-Europe solar conference. Conference proceedings: Rijeka, Croatia, 18-20 September 2012.
- Formats : PDF
Voir la fiche
-
Study on renovation to solar houses with air co...
- Auteurs : ROH H., UDAGAWA M., KUSUNOKI T.
- Date : 18/09/2012
- Langues : Anglais
- Source : EuroSun 2012: solar energy for a brighter future. ISES-Europe solar conference. Conference proceedings: Rijeka, Croatia, 18-20 September 2012.
- Formats : PDF
Voir la fiche
-
Energy-efficient homes and buildings: the beaut...
- Auteurs : Eur. Comm., Comm. Eur.
- Date : 05/2008
- Langues : Anglais
Voir la fiche
-
The application of infrared thermography for th...
- Auteurs : HABAIBEH A. al-, LUKE SIENA F.
- Date : 10/09/2012
- Langues : Anglais
- Source : 4th Jordanian IIR International Conference on Refrigeration and Air Conditioning. Proceedings: Amman, Jordan, September 10-12, 2012.
- Formats : PDF
Voir la fiche
-
Occupant experiences and satisfaction with new ...
- Auteurs : KNUDSEN H. N., THOMSEN K. E., MØRCK O.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche