Performance du mélange HFC-134a/HC-600a/HC-290 dans un compresseur conçu pour du CFC-12 et utilisant de l'huile minérale comme lubrifiant.

On the performance of HFC-134a/HC-600a/HC-290 mixture in a CFC-12 compressor with mineral oil as lubricant.

Auteurs : SEKHAR J., PREMNATH R., LAL M.

Type d'article : Article

Résumé

In this work, an existing CFC-12 domestic refrigerator was charged with HFC-134a/HC-600a/HC-290 mixture without changing the mineral oil in the compressor; the system continued to work without any problems and also had better COP. The performance testing was conducted in a temperature-controlled room as per BIS (Bureau of Indian Standards 1476). The energy consumption of the new mixture was 4 to 11% less and the actual COP obtained using the calorimetric study was 3 to 15% higher than that of CFC-12. The overall performance proved that the new mixture could be a promising substitute for CFC-12.

Détails

  • Titre original : On the performance of HFC-134a/HC-600a/HC-290 mixture in a CFC-12 compressor with mineral oil as lubricant.
  • Identifiant de la fiche : 2004-0560
  • Langues : Anglais
  • Source : EcoLibrium - vol. 2 - n. 4
  • Date d'édition : 05/2003
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.