Performance énergétique expérimentale des tours de refroidissement ouvertes utilisées dans des conditions d'approche basse et variable pour le refroidissement évaporatif indirect des immeubles.
Experimental energy performance of open cooling towers used under low and variable approach conditions for indirect evaporative cooling in buildings.
Auteurs : COSTELLOE B., FINN D.
Type d'article : Article
Résumé
The success of chilled ceilings and displacement ventilation systems as a means of sensible cooling in buildings has prompted a review of evaporative cooling technology as an effective means of generating the required cooling water. When such cooling water is generated at low approach conditions (2-5 K), at the higher temperatures required in these systems (14-18°C), very high levels of availability result. In many north western European locations the levels of availability are such that the prospect of supplanting rather than simply supplementing the refrigeration system, for sensible cooling purposes, arises. The viability of the technique, however, largely depends on achieving low approach conditions, at acceptable levels of energy performance. Hence the need to investigate the energy performance of the process. This paper presents the results of recent experimental research into: i) the achievement of low approach conditions in an evaporative cooling test rig; and ii) the energy performance of this test rig when generating cooling water, indirectly, at the temperatures required for chilled ceilings. Energy performance is presented for a range of specific conditions and typical annual efficiencies of cooling water generation are determined. Results are compared with typical energy efficiencies of conventional, vapour compression based, refrigeration systems. A significant potential for improved annual energy performance, is shown.
Détails
- Titre original : Experimental energy performance of open cooling towers used under low and variable approach conditions for indirect evaporative cooling in buildings.
- Identifiant de la fiche : 2004-2927
- Langues : Anglais
- Source : Build. Serv. Eng. Res. Technol. - vol. 24 - n. 3
- Date d'édition : 10/2003
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (3)
Voir la source
Indexation
-
Theoretical and computational analysis of close...
- Auteurs : HASAN A., SIREN K.
- Date : 06/2002
- Langues : Anglais
- Source : Energy Build. - vol. 34 - n. 5
Voir la fiche
-
Predicting thermal performance of a closed-wed ...
- Auteurs : GAN G., RIFFAT S. B.
- Date : 1999
- Langues : Anglais
- Source : Build. Serv. Eng. Res. Technol. - vol. 20 - n. 4
Voir la fiche
-
Kühldecken ohne Kältemaschine Betreiben.
- Auteurs : SPRECHER P., BORTH J., NIESSEN R.
- Date : 22/11/2000
- Langues : Allemand
- Source : DKV-Tagungsbericht Bremen. 2000.
Voir la fiche
-
Chilled ceilings: an ecological cooling system ...
- Auteurs : OLIVEIRA A., FACÃO J., AFONSO C., et al.
- Date : 09/07/2000
- Langues : Anglais
- Source : Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
Voir la fiche
-
Experimental study and modelling of cooling cei...
- Auteurs : FONSECA DIAZ N., LEBRUN J., ANDRÉ P.
- Date : 06/2010
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 33 - n. 4
- Formats : PDF
Voir la fiche