Performance sur le plan de l'environnement d'une bibliothèque centrale ventilée naturellement.
Milieuprestatie van een natuurlijk geventileerde stadsbibliotheek.
Auteurs : KRAUSSE B., COOK M., LOMAS K.
Type d'article : Article, Étude de cas
Résumé
This article describes the library building and presents the energy consumption and the internal temperatures and CO2 levels recorded in 2004-2005. The building's performance is compared to the original design criteria and good practice guidelines. Recommendations for the design of such buildings are made and the likely performance in other UK cities is assessed. It is concluded that the building used under half the energy of a standard air-conditioned building and yet, in summer, can keep the interior comfortable and up to 5°C below ambient. The design would perform equally well in the typical weather conditions experienced at 13 other UK cities, but not in London. It is concluded that deep-plan, naturally ventilated buildings with sealed facades, if well designed, could maintain thermal comfort in all but a very few UK locations, whilst consuming much less energy than even good practice standards.
Détails
- Titre original : Milieuprestatie van een natuurlijk geventileerde stadsbibliotheek.
- Identifiant de la fiche : 2009-2138
- Langues : Néerlandais
- Source : TVVL Mag. - vol. 37 - n. 3
- Date d'édition : 03/2008
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir la source
Indexation
-
Air pollution and natural ventilation in an urb...
- Auteurs : KUKADIA V., PIKE J., WHITE M.
- Date : 05/10/1997
- Langues : Anglais
- Source : CIBSE National Conference 1997. Proceedings.
Voir la fiche
-
Indoor air quality assessment of naturally vent...
- Auteurs : DIAS PEREIRA L., RODRIGUES GASPAR A., COSTA da J.J., et al.
- Date : 19/06/2018
- Langues : Anglais
- Source : CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
Voir la fiche
-
La ventilation naturelle réhabilitée.
- Auteurs : JARDINIER P., SIMONNOT J.
- Date : 04/1993
- Langues : Français
- Source : Chaud Froid Plomb. - vol. 47 - n. 546
Voir la fiche
-
Filtro de Kalman para a determinação do ar num ...
- Auteurs : DUARTE R., GOMES M. G., MORET RODRIGUES A.
- Date : 19/06/2018
- Langues : Portugais
- Source : CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
Voir la fiche
-
Naturally air-conditioned nearly zero-energy ho...
- Auteurs : PATIDAR Y., BOKEL R.
- Date : 12/2021
- Langues : Anglais
- Source : REHVA Journal - vol. 58 - n. 6
- Formats : PDF
Voir la fiche