Document IIF

Pertes dues aux séquences de mise en route dans les appareils domestiques: analyse expérimentale et théorique.

Cycling losses in domestic appliances: an experimental and theoretical analysis.

Auteurs : JANSSEN M. J. P., WIT J. A. de, KUIJPERS L. J. M.

Type d'article : Article, Article de la RIF

Résumé

The on/off mode is the method of control usually applied in domestic refrigeration equipment. Owing to this method of operation, cycling losses occur which depend on the on/off cycle length, the dimensions of the heat exchangers, etc. It is the aim of this study to analyse these cycling losses in detail, both numerically and experimentally. Two operation modes for cycling are selected: the condenser closed during the off-period and the condenser open during the off-period. Both cycling operation modes are compared with a continuously running system.

Documents disponibles

Format PDF

Pages : 152-158

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Cycling losses in domestic appliances: an experimental and theoretical analysis.
  • Identifiant de la fiche : 30001895
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 15 - n. 3
  • Date d'édition : 1992

Liens


Voir d'autres articles du même numéro (7)
Voir la source