Document IIF

Simulation numérique de cycles de réfrigération à tubes capillaires dans des cycles par tout ou rien.

Numerical simulation of refrigeration cycles with capillary tubes in on/off cycling mode.

Résumé

A mathematical model is presented as a tool to describe the on/off cycling behaviour of a household refrigerator. The charge of the HC refrigerant isobutane is very low, only about one tenth of the amount of oil in the compressor. Therefore the sorption of refrigerant in the oil has to be taken into consideration. A submodel for the transient sorption in a hermetic compressor is developed and parameters are obtained experimentally. In simulation experiments the localisation of refrigerant in the machine is explained. It can be shown, that temperatures in the oilsump significantly influence the superheat area of the evaporator.

Documents disponibles

Format PDF

Pages : 2000-1

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Numerical simulation of refrigeration cycles with capillary tubes in on/off cycling mode.
  • Identifiant de la fiche : 2002-0181
  • Langues : Anglais
  • Source : Final proceedings of the 4th IIR-Gustav Lorentzen Conference on Natural Working Fluids at Purdue.
  • Date d'édition : 25/07/2000

Liens


Voir d'autres communications du même compte rendu (65)
Voir le compte rendu de la conférence