Document IIF

Pompe à chaleur à compression partielle hybride et à transformateur de chaleur.

Partial hybrid compression heat transformer heat pump.

Numéro : 1034

Auteurs : STAICOVICI M. D. N.

Résumé

Paper presents new Partial Hybrid Compression Heat Transformer (PHCHT) heat pump, joining Partial Hybrid Compression and Heat Transformer in an Absorption (ATS) and Mechanical Compression (MVCTS) synergy. A lemma proves heating COP. PHCHT is modelled. Heat is produced and stored during night time for entire day use. ATS and MVCTS operate with ammonia-water and ammonia. 1st results hold for yearly household WWH of ≈ 55oC for a selection of 36 cold and temperate climates. Ground water and air are heat and sink. Average temperatures come of weather channels, 𝑇ℎ𝑠 ∈ [6,5℃, 23,0℃] and 𝑇𝑛𝑖𝑔ℎ𝑡 𝑎𝑖𝑟 ∈ [−3,5℃, +8,45℃]. COP is by (10 − 120)% higher comparatively. 2nd results describe a typical cold night zone (Romania). Yearly COP is higher by ~ 150 % comparatively. Despite that PHCHT needs cca. twice more ground heat as
compared to MVC heat pump, results show PHCHT could bring important primary energy savings worlwide.

Documents disponibles

Format PDF

Pages : 6p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Partial hybrid compression heat transformer heat pump.
  • Identifiant de la fiche : 30027898
  • Langues : Anglais
  • Sujet : Technologie
  • Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
  • Date d'édition : 07/12/2020
  • DOI : http://dx.doi.org/10.18462/iir.gl.2020.1064
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (120)
Voir le compte rendu de la conférence