Résumé
Interest in the supercritical carbon dioxide (S-CO2) Brayton cycle technology is gradually increasing due to high efficiency at moderate turbine inlet temperature and potential to achieve high compactness of the whole power conversion system. As a part of research activities on the S-CO2 Brayton cycle technology development, Supercritical CO2 Pressurization Experiment (SCO2PE) facility was constructed for lab scale CO2 compression experiment near the critical point. SCO2PE facility operation is focused on resolving issues in a compressor design and operation near the critical point of CO2. From the SCO2PE operation experience, performance measurement uncertainty issues in a low pressure ratio compressor were identified and these issues become generic if a compressor operates near the critical point. Very high uncertainty on performance measurement was observed due to the peak region in thermodynamic property variation of CO2 near the critical point and low pressure ratio operation of the compressor. High pressure ratio compressor design and operation can mitigate high uncertainty issues in performance measurement. However, low pressure ratio operation cannot be ignored since low pressure ratio operation is always involved during a part load operation or transient operation of a power conversion system. Thus, an alternative approach was suggested to secure reliability of performance estimation from the basic measurement.
Détails
- Titre original : Issues in performance measurement of CO2 compressor near the critical point.
- Identifiant de la fiche : 30016903
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 94
- Date d'édition : 05/02/2016
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2015.10.063
Liens
Voir d'autres articles du même numéro (46)
Voir la source
Indexation
-
Thèmes :
Compresseurs;
CO2 - Mots-clés : Brayton; R744; Point critique; Performance; Frigorigène; Compresseur; CO2
-
Theoretical performance of carbon dioxide in su...
- Auteurs : BULLOCK C. E.
- Date : 06/10/1997
- Langues : Anglais
- Source : Refrigerants for the 21st century. ASHRAE-NIST refrigerants Conference.
Voir la fiche
-
Thermodynamic and phase behaviour of natural re...
- Auteurs : BONDARENKO V., KULESHOV D., MAZUR V., et al.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche
-
Utilization of CO2 and R1234ze(E) as refrigeran...
- Auteurs : XIE J., VALTZ A., COQUELET C., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Regenerated air cycle potentials in heat pump a...
- Auteurs : YUAN H., ZHANG C. L.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Malone refrigeration.
- Auteurs : SWIFT G. W.
- Date : 23/06/1993
- Langues : Anglais
- Source : Proceedings of the 1993 Non-Fluorocarbon Refrigeration and Air-Conditioning Technology Workshop.
Voir la fiche