Procédé de redémarrage d'une colonne auxiliaire de séparation argon/oxygène.

Process for restarting an auxiliary column for argon/oxygen separation.

Auteurs : POPA V., PINTILIE M., SERBAN A., et al.

Résumé

The paper presents the process and the corresponding installation for restarting an auxiliary column after an interruption in operation. This auxiliary column is coupled with a principal air distillation apparatus. During the stoppage of the mean air separation column, the liquid contained in the auxiliary column is stored, then recycled. During restarting an argon column, the liquid in the base of the column is maintained at a constant level. Collected liquid is used to re-inventory the separation section of the argon column with liquid before restarting that column or upon restart of gas supply to the column.

Documents disponibles

Format PDF

Pages : 2002-1

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Process for restarting an auxiliary column for argon/oxygen separation.
  • Identifiant de la fiche : 2003-2683
  • Langues : Anglais
  • Source : Cryogenics 2002. Proceedings of the 7th Cryogenics Conference
  • Date d'édition : 23/04/2002

Liens


Voir d'autres communications du même compte rendu (36)
Voir le compte rendu de la conférence